Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,456
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0039 # 04 Y:1985 | 04 | 1985 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $22,508 | $40,000 | Implemented |
CO0039 # 05 Y:1985 | 05 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,490 | $500 | Implemented |
CO0039 # 06 Y:1985 | 06 | 1985 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $503 | $400 | Implemented |
CO0039 # 07 Y:1985 | 07 | 1985 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $964 | $20,000 | Implemented |
CO0039 # 08 Y:1985 | 08 | 1985 | INSTALL TURBULATORS | $8,655 | $1,700 | Implemented |
CO0040 # 01 Y:1985 | 01 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $253 | $250 | Implemented |
CO0040 # 02 Y:1985 | 02 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $666 | $500 | Implemented |
CO0040 # 03 Y:1985 | 03 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $4,591 | $200 | Implemented |
CO0040 # 04 Y:1985 | 04 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $475 | $534 | Implemented |
CO0040 # 05 Y:1985 | 05 | 1985 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,363 | $200 | Not Implemented |
CO0036 # 01 Y:1985 | 01 | 1985 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $179 | $0 | Implemented |
CO0036 # 02 Y:1985 | 02 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $179 | $200 | Not Implemented |
CO0036 # 03 Y:1985 | 03 | 1985 | REDESIGN PROCESS | $593 | $200 | Implemented |
CO0036 # 04 Y:1985 | 04 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,393 | $200 | Implemented |
CO0036 # 05 Y:1985 | 05 | 1985 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,607 | $5,000 | Not Implemented |
CO0036 # 06 Y:1985 | 06 | 1985 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,309 | $2,400 | Not Implemented |
CO0036 # 07 Y:1985 | 07 | 1985 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $3,744 | $10,000 | Not Implemented |
CO0036 # 08 Y:1985 | 08 | 1985 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $8,457 | $1,000 | Implemented |
CO0036 # 09 Y:1985 | 09 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,330 | $2,816 | Not Implemented |
CO0036 # 10 Y:1985 | 10 | 1985 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $669 | $932 | Implemented |
CO0036 # 11 Y:1985 | 11 | 1985 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $6,642 | $390 | Implemented |
CO0036 # 12 Y:1985 | 12 | 1985 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $750 | $340 | Not Implemented |
CO0037 # 01 Y:1985 | 01 | 1985 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $229 | $50 | Not Implemented |
CO0037 # 02 Y:1985 | 02 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,071 | $500 | Implemented |
CO0037 # 03 Y:1985 | 03 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,658 | $8,000 | Not Implemented |