Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,715
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0323 # 02 Y:1995 | 02 | 1995 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $18,310 | $55,500 | Implemented |
CO0323 # 03 Y:1995 | 03 | 1995 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $16,090 | $42,500 | Not Implemented |
CO0323 # 04 Y:1995 | 04 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $11,370 | $8,790 | Implemented |
CO0323 # 05 Y:1995 | 05 | 1995 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $9,950 | $34,080 | Not Implemented |
CO0323 # 06 Y:1995 | 06 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,520 | $4,210 | Implemented |
CO0323 # 07 Y:1995 | 07 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,000 | $7,800 | Not Implemented |
CO0322 # 01 Y:1995 | 01 | 1995 | INSULATE BARE EQUIPMENT | $131,920 | $35,180 | Not Implemented |
CO0322 # 02 Y:1995 | 02 | 1995 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $58,530 | $85,020 | Not Implemented |
CO0322 # 03 Y:1995 | 03 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $12,530 | $830 | Implemented |
CO0322 # 04 Y:1995 | 04 | 1995 | INSULATE BARE EQUIPMENT | $12,270 | $16,040 | Not Implemented |
CO0322 # 05 Y:1995 | 05 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,570 | $19,930 | Implemented |
CO0322 # 06 Y:1995 | 06 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,320 | $500 | Implemented |
CO0322 # 07 Y:1995 | 07 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,650 | $7,690 | Not Implemented |
CO0321 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,070 | $410 | Implemented |
CO0321 # 02 Y:1995 | 02 | 1995 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,600 | $9,960 | Not Implemented |
CO0321 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $670 | $830 | Implemented |
CO0321 # 04 Y:1995 | 04 | 1995 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $410 | $250 | Implemented |
CO0321 # 05 Y:1995 | 05 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $230 | $100 | Not Implemented |
CO0321 # 06 Y:1995 | 06 | 1995 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $200 | $100 | Not Implemented |
CO0320 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,920 | $57,500 | Not Implemented |
CO0320 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,700 | $3,690 | Implemented |
CO0320 # 03 Y:1994 | 03 | 1994 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $3,430 | $13,000 | Not Implemented |
CO0320 # 04 Y:1994 | 04 | 1994 | REMOVE ROLLERS FROM THE MACHINES AND CLEAN IN A CLOSED SOLVENT CLEANER | $2,640 | $1,750 | Implemented |
CO0320 # 05 Y:1994 | 05 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,470 | $2,580 | Not Implemented |
CO0320 # 06 Y:1994 | 06 | 1994 | DISTILL CONTAMINATED SOLVENTS FOR REUSE | $1,640 | $5,080 | Not Implemented |