Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,133
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0061 # 08 Y:2010 | 08 | 2010 | INSULATE BARE EQUIPMENT | $246 | $400 | Not Implemented |
DL0061 # 09 Y:2010 | 09 | 2010 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $438 | $1,100 | Not Implemented |
DL0061 # 10 Y:2010 | 10 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $18,529 | $47,000 | Implemented |
DL0061 # 11 Y:2010 | 11 | 2010 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $4,440 | $13,400 | Not Implemented |
DL0061 # 12 Y:2010 | 12 | 2010 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,690 | $5,550 | Not Implemented |
DL0061 # 13 Y:2010 | 13 | 2010 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $860 | $8,000 | Not Implemented |
DL0061 # 14 Y:2010 | 14 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,396 | $20,804 | Implemented |
DL0060 # 01 Y:2010 | 01 | 2010 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $65,458 | $79,125 | Not Implemented |
DL0060 # 02 Y:2010 | 02 | 2010 | INSULATE BARE EQUIPMENT | $12,645 | $14,080 | Not Implemented |
DL0060 # 03 Y:2010 | 03 | 2010 | INSTALL OCCUPANCY SENSORS | $2,705 | $422 | Not Implemented |
DL0060 # 04 Y:2010 | 04 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,957 | $26,400 | Implemented |
DL0060 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,557 | $8,750 | Not Implemented |
DL0060 # 06 Y:2010 | 06 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,362 | $21,600 | Implemented |
DL0059 # 01 Y:2010 | 01 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $5,800 | $520 | Implemented |
DL0059 # 02 Y:2010 | 02 | 2010 | USE COMPRESSOR AIR FILTERS | $6,340 | $12,965 | Implemented |
DL0059 # 03 Y:2010 | 03 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $7,300 | $650 | Not Implemented |
DL0059 # 04 Y:2010 | 04 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,931 | $40 | Implemented |
DL0059 # 05 Y:2010 | 05 | 2010 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,616 | $400 | Implemented |
DL0059 # 06 Y:2010 | 06 | 2010 | INSTALL TIMERS AND/OR THERMOSTATS | $2,552 | $1,038 | Implemented |
DL0059 # 07 Y:2010 | 07 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $580 | $40 | Implemented |
DL0058 # 01 Y:2010 | 01 | 2010 | REDUCE VENTILATION AIR | $152,300 | $500,000 | Not Implemented |
DL0058 # 02 Y:2010 | 02 | 2010 | INSTALL FOSSIL FUEL MAKE-UP AIR UNIT | $95,200 | $250,000 | Not Implemented |
DL0058 # 03 Y:2010 | 03 | 2010 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $143,000 | $4,268 | Implemented |
DL0058 # 04 Y:2010 | 04 | 2010 | DISCONNECT BALLASTS | $12,500 | $350 | Not Implemented |
DL0058 # 05 Y:2010 | 05 | 2010 | TURN OFF EQUIPMENT WHEN NOT IN USE | $11,800 | $250 | Implemented |