Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

387

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0780 # 05 Y:2004 05 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $4,772 $500 Implemented
GT0780 # 10 Y:2004 10 2004 CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS $12,344 $20,000 Not Implemented
GT0780 # 02 Y:2004 02 2004 INSTALL TURBULATORS $11,482 $12,800 n/a
GT0780 # 03 Y:2004 03 2004 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,654 $10,261 Implemented
GT0780 # 07 Y:2004 07 2004 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $1,729 $1,209 Implemented
GT0780 # 01 Y:2004 01 2004 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $6,020 $11,903 Implemented
GT0780 # 06 Y:2004 06 2004 COMBINE UTILITY METERS $23,320 $0 Not Implemented
GT0780 # 09 Y:2004 09 2004 REPAIR AND ELIMINATE STEAM LEAKS $7,453 $900 Implemented
GT0780 # 12 Y:2004 12 2004 CONTROL PRESSURE ON STEAMER OPERATIONS $2,490 $800 Implemented
GT0780 # 04 Y:2004 04 2004 UTILIZE A LESS EXPENSIVE COOLING METHOD $25,046 $92,125 Not Implemented
GT0780 # 11 Y:2004 11 2004 RECOVER WASTE HEAT FROM EQUIPMENT $1,325 $1,600 Not Implemented
GT0780 # 08 Y:2004 08 2004 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,512 $0 Not Implemented
GT0759 # 07 Y:2003 07 2003 USE RADIANT HEATER FOR SPOT HEATING $5,960 $2,190 Implemented
GT0759 # 06 Y:2003 06 2003 IMPROVE COMBUSTION CONTROL CAPABILITY $287,380 $24,500 n/a
GT0759 # 02 Y:2003 02 2003 INSULATE BARE EQUIPMENT $770,950 $340,200 Not Implemented
GT0759 # 05 Y:2003 05 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $157,690 $210,000 n/a
GT0759 # 04 Y:2003 04 2003 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $200,910 $20,900 n/a
GT0759 # 08 Y:2003 08 2003 RECOVER WASTE HEAT FROM EQUIPMENT $89,620 $108,930 Implemented
GT0759 # 01 Y:2003 01 2003 COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER $5,870 $3,000 Implemented
GT0759 # 03 Y:2003 03 2003 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $33,765 $188,200 Implemented
GT0743 # 01 Y:2002 01 2002 USE MINIMUM STEAM OPERATING PRESSURE $1,259 $0 Implemented
GT0743 # 02 Y:2002 02 2002 OPERATE BOILERS ON HIGH FIRE SETTING $5,598 $0 Not Implemented
GT0743 # 07 Y:2002 07 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,206 $17,240 Not Implemented
GT0743 # 06 Y:2002 06 2002 RECOVER WASTE HEAT FROM EQUIPMENT $2,792 $5,050 Not Implemented
GT0743 # 04 Y:2002 04 2002 USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER $10,781 $1,720 Implemented