IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,675

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
HO0126 # 02 Y:1996 02 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,280 $6,484 Implemented
HO0126 # 03 Y:1996 03 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,975 $3,110 Implemented
HO0126 # 04 Y:1996 04 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,573 $400 Implemented
HO0126 # 05 Y:1996 05 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,352 $180 Implemented
HO0126 # 06 Y:1996 06 1996 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $5,430 $0 Not Implemented
HO0125 # 01 Y:1996 01 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,210 $1,200 Implemented
HO0125 # 02 Y:1996 02 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,138 $9,130 Implemented
HO0125 # 03 Y:1996 03 1996 REPAIR AND ELIMINATE STEAM LEAKS $175 $100 Implemented
HO0125 # 04 Y:1996 04 1996 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $1,400 $5,000 Not Implemented
HO0124 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,051 $11,011 Implemented
HO0124 # 02 Y:1995 02 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $51 $150 Not Implemented
HO0124 # 03 Y:1995 03 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $357 $0 Implemented
HO0124 # 04 Y:1995 04 1995 USE RADIANT HEATER FOR SPOT HEATING $714 $2,400 Implemented
HO0123 # 01 Y:1995 01 1995 ADD AREA LIGHTING SWITCHES $2,534 $200 Implemented
HO0123 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,424 $10,340 Implemented
HO0123 # 03 Y:1995 03 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $752 $1,492 Not Implemented
HO0123 # 04 Y:1995 04 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,559 $600 Implemented
HO0123 # 05 Y:1995 05 1995 BURN WASTE OIL FOR HEAT $7,100 $1,500 Not Implemented
HO0122 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $773 $1,733 Implemented
HO0122 # 02 Y:1995 02 1995 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $332 $0 Not Implemented
HO0122 # 03 Y:1995 03 1995 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES $1,952 $750 Implemented
HO0122 # 04 Y:1995 04 1995 INSTALL OCCUPANCY SENSORS $1,151 $400 Not Implemented
HO0121 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,913 $2,160 Implemented
HO0121 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,437 $2,318 Implemented
HO0121 # 03 Y:1995 03 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $739 $598 Implemented