Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,660
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0059 # 05 Y:1993 | 05 | 1993 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $264 | $0 | Implemented |
IA0059 # 06 Y:1993 | 06 | 1993 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $8,376 | $1,543 | Not Implemented |
IA0059 # 07 Y:1993 | 07 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,828 | $1,740 | Implemented |
IA0059 # 08 Y:1993 | 08 | 1993 | INSTALL OCCUPANCY SENSORS | $1,072 | $1,530 | Implemented |
IA0059 # 09 Y:1993 | 09 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $978 | $120 | Implemented |
IA0058 # 01 Y:1993 | 01 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,306 | $1,000 | Implemented |
IA0058 # 02 Y:1993 | 02 | 1993 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $416 | $1,200 | Not Implemented |
IA0058 # 03 Y:1993 | 03 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,091 | $4,600 | Implemented |
IA0058 # 04 Y:1993 | 04 | 1993 | USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR | $88,602 | $95,000 | Not Implemented |
IA0058 # 05 Y:1993 | 05 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $13,994 | $250 | Implemented |
IA0058 # 06 Y:1993 | 06 | 1993 | INSTALL OCCUPANCY SENSORS | $4,847 | $1,899 | Not Implemented |
IA0058 # 07 Y:1993 | 07 | 1993 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $7,910 | $30,000 | Not Implemented |
IA0058 # 08 Y:1993 | 08 | 1993 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $537 | $1,100 | Not Implemented |
IA0057 # 01 Y:1993 | 01 | 1993 | TURN OFF EQUIPMENT WHEN NOT IN USE | $3,530 | $433 | Implemented |
IA0057 # 02 Y:1993 | 02 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,451 | $2,374 | Implemented |
IA0057 # 03 Y:1993 | 03 | 1993 | INSTALL OCCUPANCY SENSORS | $931 | $2,367 | Implemented |
IA0057 # 04 Y:1993 | 04 | 1993 | COVER OPEN TANKS | $533 | $375 | Implemented |
IA0057 # 05 Y:1993 | 05 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $154 | $380 | Not Implemented |
IA0056 # 01 Y:1993 | 01 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $107,264 | $278,300 | Not Implemented |
IA0056 # 02 Y:1993 | 02 | 1993 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $36,020 | $56,799 | Not Implemented |
IA0056 # 03 Y:1993 | 03 | 1993 | TURN OFF STEAM TRACING DURING MILD WEATHER | $68,883 | $0 | Implemented |
IA0056 # 04 Y:1993 | 04 | 1993 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $13,373 | $0 | Implemented |
IA0056 # 05 Y:1993 | 05 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,373 | $971 | Implemented |
IA0056 # 06 Y:1993 | 06 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,662 | $1,000 | Implemented |
IA0056 # 07 Y:1993 | 07 | 1993 | INSTALL / REPAIR INSULATION ON STEAM LINES | $5,430 | $3,676 | Implemented |