ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0554 # 05 Y:2000 | 05 | 2000 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $620 | $2,000 | Not Implemented |
KU0554 # 02 Y:2000 | 02 | 2000 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,829 | $0 | Implemented |
KU0554 # 04 Y:2000 | 04 | 2000 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,445 | $0 | Implemented |
KU0554 # 01 Y:2000 | 01 | 2000 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $2,875 | $13,000 | Not Implemented |
KU0554 # 03 Y:2000 | 03 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,480 | $1,810 | Not Implemented |
KU0553 # 04 Y:2000 | 04 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,081 | $90 | Not Implemented |
KU0553 # 03 Y:2000 | 03 | 2000 | INSULATE BARE EQUIPMENT | $2,117 | $3,116 | Not Implemented |
KU0553 # 02 Y:2000 | 02 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,466 | $2,560 | Not Implemented |
KU0553 # 05 Y:2000 | 05 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $618 | $494 | Not Implemented |
KU0553 # 01 Y:2000 | 01 | 2000 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $2,828 | $6,750 | Not Implemented |
KU0553 # 06 Y:2000 | 06 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $374 | $230 | Not Implemented |
KU0552 # 05 Y:2000 | 05 | 2000 | RECOVER AND REUSE WASTE MATERIAL | $12,000 | $11,400 | Not Implemented |
KU0552 # 04 Y:2000 | 04 | 2000 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $3,315 | $6,000 | Not Implemented |
KU0552 # 03 Y:2000 | 03 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $378 | $206 | Not Implemented |
KU0552 # 02 Y:2000 | 02 | 2000 | OPTIMIZE PLANT POWER FACTOR | $699 | $725 | Not Implemented |
KU0552 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $900 | $600 | Not Implemented |
KU0551 # 05 Y:2000 | 05 | 2000 | RECOVER AND REUSE WASTE MATERIAL | $26,760 | $37,200 | Not Implemented |
KU0551 # 04 Y:2000 | 04 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $827 | $700 | Not Implemented |
KU0551 # 02 Y:2000 | 02 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,010 | $60 | Not Implemented |
KU0551 # 03 Y:2000 | 03 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,370 | $890 | Not Implemented |
KU0551 # 01 Y:2000 | 01 | 2000 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $8,821 | $18,000 | Not Implemented |
KU0550 # 01 Y:2000 | 01 | 2000 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $8,989 | $17,000 | Not Implemented |
KU0550 # 03 Y:2000 | 03 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,038 | $20 | Not Implemented |
KU0550 # 04 Y:2000 | 04 | 2000 | AUTOMATE FINISHING PROCESS | $101,920 | $34,000 | Not Implemented |
KU0550 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,255 | $650 | Not Implemented |