IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

183

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0170 # 05 Y:1989 05 1989 REPAIR OR REPLACE STEAM TRAPS $355 $365 Not Implemented
MA0170 # 04 Y:1989 04 1989 AIR CONDITION ONLY SPACE NECESSARY $4,707 $200 Not Implemented
MA0170 # 07 Y:1989 07 1989 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,248 $2,000 Not Implemented
MA0170 # 06 Y:1989 06 1989 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $119 $150 Not Implemented
MA0170 # 01 Y:1989 01 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $922 $575 Not Implemented
MA0170 # 02 Y:1989 02 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $614 $60 Not Implemented
MA0170 # 03 Y:1989 03 1989 INSTALL SET-BACK TIMERS $396 $195 Not Implemented
MA0170 # 08 Y:1989 08 1989 INSTALL TIMERS AND/OR THERMOSTATS $1,999 $180 Not Implemented
MA0169 # 01 Y:1989 01 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,187 $1,752 Not Implemented
MA0169 # 03 Y:1989 03 1989 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $1,087 $0 Implemented
MA0169 # 05 Y:1989 05 1989 INSTALL TIMERS AND/OR THERMOSTATS $405 $0 Not Implemented
MA0169 # 02 Y:1989 02 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $582 $740 Implemented
MA0169 # 04 Y:1989 04 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $231 $0 Implemented
MA0167 # 06 Y:1989 06 1989 INSULATE BARE EQUIPMENT $2,131 $0 Not Implemented
MA0168 # 01 Y:1989 01 1989 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $14,558 $10,000 Not Implemented
MA0166 # 02 Y:1989 02 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $3,628 $3,450 Not Implemented
MA0165 # 03 Y:1989 03 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,081 $500 Not Implemented
MA0167 # 05 Y:1989 05 1989 RECOVER WASTE HEAT FROM EQUIPMENT $1,828 $500 Not Implemented
MA0168 # 03 Y:1989 03 1989 INSTALL SET-BACK TIMERS $228 $195 Not Implemented
MA0165 # 02 Y:1989 02 1989 INSTALL TIMERS AND/OR THERMOSTATS $1,015 $840 Implemented
MA0166 # 01 Y:1989 01 1989 ADD AIR SHIELDS TO TRUCKS TO INCREASE FUEL MILEAGE $19,320 $18,000 Not Implemented
MA0167 # 04 Y:1989 04 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,411 $300 Not Implemented
MA0166 # 03 Y:1989 03 1989 INSTALL TIMERS AND/OR THERMOSTATS $1,130 $180 Implemented
MA0165 # 04 Y:1989 04 1989 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $24,781 $22,722 Not Implemented
MA0168 # 02 Y:1989 02 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,218 $0 Implemented