Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,050
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0259 # 03 Y:2014 | 03 | 2014 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,650 | $3,100 | Implemented |
MI0259 # 04 Y:2014 | 04 | 2014 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,728 | $760 | Implemented |
MI0259 # 05 Y:2014 | 05 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,251 | $9,720 | Not Implemented |
MI0259 # 06 Y:2014 | 06 | 2014 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $3,604 | $8,400 | Not Implemented |
MI0259 # 07 Y:2014 | 07 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,090 | $1,040 | Implemented |
MI0259 # 08 Y:2014 | 08 | 2014 | INSTALL OCCUPANCY SENSORS | $1,545 | $622 | Implemented |
MI0259 # 09 Y:2014 | 09 | 2014 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $820 | $80 | Not Implemented |
MI0259 # 10 Y:2014 | 10 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $629 | $1,660 | Implemented |
MI0259 # 11 Y:2014 | 11 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $183 | $80 | Implemented |
MI0256 # 01 Y:2014 | 01 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $23,834 | $20,160 | Not Implemented |
MI0256 # 02 Y:2014 | 02 | 2014 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $23,626 | $13,599 | Implemented |
MI0256 # 03 Y:2014 | 03 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $23,619 | $80 | Implemented |
MI0256 # 04 Y:2014 | 04 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,420 | $1,660 | Implemented |
MI0256 # 05 Y:2014 | 05 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $11,196 | $3,960 | Implemented |
MI0256 # 06 Y:2014 | 06 | 2014 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $7,634 | $80 | Implemented |
MI0256 # 07 Y:2014 | 07 | 2014 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,540 | $3,240 | Not Implemented |
MI0256 # 08 Y:2014 | 08 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,517 | $3,360 | Not Implemented |
MI0256 # 09 Y:2014 | 09 | 2014 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,183 | $6,800 | Not Implemented |
MI0253 # 01 Y:2013 | 01 | 2013 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $174,761 | $506,800 | Not Implemented |
MI0253 # 02 Y:2013 | 02 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $53,448 | $80 | Implemented |
MI0253 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43,154 | $52,122 | Implemented |
MI0253 # 04 Y:2013 | 04 | 2013 | INSTALL OCCUPANCY SENSORS | $36,919 | $2,300 | Not Implemented |
MI0253 # 05 Y:2013 | 05 | 2013 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $22,448 | $1,680 | Implemented |
MI0253 # 06 Y:2013 | 06 | 2013 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $4,676 | $1,660 | Implemented |
MI0253 # 07 Y:2013 | 07 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,885 | $4,840 | Not Implemented |