IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

294

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0509 # 06 Y:2014 06 2014 INSULATE FEEDWATER TANK $198 $75 Implemented
NC0509 # 07 Y:2014 07 2014 INSTALL / REPAIR INSULATION ON STEAM LINES $792 $787 Not Implemented
NC0509 # 08 Y:2014 08 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $585 $50 Not Implemented
NC0509 # 09 Y:2014 09 2014 RECOVER WASTE HEAT FROM EQUIPMENT $725 $450 Implemented
NC0509 # 10 Y:2014 10 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $270 $100 Implemented
NC0509 # 11 Y:2014 11 2014 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $85 $105 Implemented
NC0508 # 01 Y:2014 01 2014 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $9,684 $2,200 Implemented
NC0508 # 02 Y:2014 02 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $865 $100 Implemented
NC0508 # 03 Y:2014 03 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,274 $1,950 Not Implemented
NC0508 # 04 Y:2014 04 2014 RECOVER WASTE HEAT FROM EQUIPMENT $1,952 $2,300 Implemented
NC0508 # 05 Y:2014 05 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,695 $28,977 Implemented
NC0508 # 06 Y:2014 06 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $520 $4,006 Not Implemented
NC0508 # 07 Y:2014 07 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,026 $240 Implemented
NC0508 # 08 Y:2014 08 2014 INSTALL OCCUPANCY SENSORS $359 $574 Not Implemented
NC0508 # 09 Y:2014 09 2014 DEVELOP A REPAIR/REPLACE POLICY $1,128 $4,256 Not Implemented
NC0507 # 01 Y:2014 01 2014 UTILIZE A LESS EXPENSIVE COOLING METHOD $13,167 $23,000 Not Implemented
NC0507 # 02 Y:2014 02 2014 RECOVER WASTE HEAT FROM EQUIPMENT $16,846 $43,969 Not Implemented
NC0507 # 03 Y:2014 03 2014 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $51,724 $62,000 Not Implemented
NC0507 # 04 Y:2014 04 2014 KEEP BOILER TUBES CLEAN $6,811 $2,000 Implemented
NC0507 # 05 Y:2014 05 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $806 $650 Not Implemented
NC0507 # 06 Y:2014 06 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $264 $50 Implemented
NC0507 # 07 Y:2014 07 2014 INSTALL OCCUPANCY SENSORS $1,828 $1,018 Not Implemented
NC0507 # 08 Y:2014 08 2014 USE PHOTOCELL CONTROLS $72 $80 Not Implemented
NC0507 # 09 Y:2014 09 2014 DEVELOP A REPAIR/REPLACE POLICY $2,801 $10,912 Implemented
NC0505 # 01 Y:2014 01 2014 MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT $1,293 $200 Implemented