IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,985

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0049 # 05 Y:1995 05 1995 INSTALL OCCUPANCY SENSORS $1,245 $3,600 Not Implemented
NC0048 # 01 Y:1995 01 1995 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,504 $0 Not Implemented
NC0048 # 02 Y:1995 02 1995 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $112 $100 Not Implemented
NC0048 # 03 Y:1995 03 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $195 $38 Not Implemented
NC0048 # 04 Y:1995 04 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $589 $180 Not Implemented
NC0048 # 05 Y:1995 05 1995 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,762 $1,000 Not Implemented
NC0048 # 06 Y:1995 06 1995 INSULATE BARE EQUIPMENT $2,212 $6,061 Not Implemented
NC0047 # 01 Y:1995 01 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,390 $60 Implemented
NC0047 # 02 Y:1995 02 1995 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,105 $320 Not Implemented
NC0047 # 03 Y:1995 03 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,787 $3,000 Implemented
NC0047 # 04 Y:1995 04 1995 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,881 $1,500 Not Implemented
NC0047 # 05 Y:1995 05 1995 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $4,139 $3,000 Not Implemented
NC0047 # 06 Y:1995 06 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,550 $4,020 Implemented
NC0047 # 07 Y:1995 07 1995 INSULATE BARE EQUIPMENT $5,148 $906 Not Implemented
NC0046 # 01 Y:1995 01 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $251 $330 Implemented
NC0046 # 02 Y:1995 02 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,179 $6,550 Implemented
NC0046 # 03 Y:1995 03 1995 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $13,396 $12,000 Not Implemented
NC0046 # 04 Y:1995 04 1995 MAKE ICE DURING OFF PEAK HOURS FOR COOLING $18,043 $36,000 Not Implemented
NC0046 # 05 Y:1995 05 1995 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $605 $550 Implemented
NC0046 # 06 Y:1995 06 1995 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $784 $600 Implemented
NC0045 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $7,193 $5,730 Not Implemented
NC0045 # 02 Y:1994 02 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,703 $2,581 Not Implemented
NC0045 # 03 Y:1994 03 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,943 $630 Implemented
NC0045 # 04 Y:1994 04 1994 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,312 $720 Not Implemented
NC0045 # 05 Y:1994 05 1994 USE PHOTOCELL CONTROLS $2,490 $210 Not Implemented