Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,027
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
RU0044 # 03 Y:1988 | 03 | 1988 | INSTALL / REPAIR INSULATION ON STEAM LINES | $1,286 | $390 | Implemented |
RU0044 # 04 Y:1988 | 04 | 1988 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,369 | $3,400 | Not Implemented |
RU0044 # 05 Y:1988 | 05 | 1988 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,386 | $0 | Not Implemented |
RU0044 # 06 Y:1988 | 06 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $456 | $0 | Implemented |
RU0044 # 07 Y:1988 | 07 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $363 | $500 | Implemented |
RU0045 # 01 Y:1988 | 01 | 1988 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,025 | $0 | Implemented |
RU0045 # 02 Y:1988 | 02 | 1988 | IMPROVE LUBRICATION PRACTICES | $356 | $800 | Not Implemented |
RU0045 # 03 Y:1988 | 03 | 1988 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $2,714 | $11,000 | Not Implemented |
RU0045 # 04 Y:1988 | 04 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $549 | $1,038 | Implemented |
RU0045 # 05 Y:1988 | 05 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $596 | $500 | Implemented |
RU0036 # 01 Y:1988 | 01 | 1988 | AIR CONDITION ONLY SPACE NECESSARY | $2,449 | $4,244 | Not Implemented |
RU0036 # 02 Y:1988 | 02 | 1988 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $3,900 | $26,730 | Not Implemented |
RU0036 # 03 Y:1988 | 03 | 1988 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $2,637 | $2,780 | Not Implemented |
RU0036 # 04 Y:1988 | 04 | 1988 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,523 | $2,268 | Not Implemented |
RU0036 # 05 Y:1988 | 05 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,611 | $0 | Implemented |
RU0036 # 06 Y:1988 | 06 | 1988 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,145 | $2,600 | Not Implemented |
RU0036 # 07 Y:1988 | 07 | 1988 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $9,862 | $4,000 | Not Implemented |
RU0037 # 01 Y:1988 | 01 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $657 | $0 | Implemented |
RU0037 # 02 Y:1988 | 02 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,052 | $0 | Implemented |
RU0037 # 03 Y:1988 | 03 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $775 | $96 | Implemented |
RU0037 # 04 Y:1988 | 04 | 1988 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,970 | $4,500 | Implemented |
RU0037 # 05 Y:1988 | 05 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $719 | $3,556 | Not Implemented |
RU0037 # 06 Y:1988 | 06 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $392 | $500 | Not Implemented |
RU0038 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,542 | $2,386 | Implemented |
RU0038 # 02 Y:1988 | 02 | 1988 | INSTALL SET-BACK TIMERS | $6,581 | $0 | Implemented |