Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,072
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0295 # 06 Y:2002 | 06 | 2002 | INSTALL SKYLIGHTS | $543 | $1,200 | Not Implemented |
SD0295 # 07 Y:2002 | 07 | 2002 | RECOVER AND REUSE WASTE MATERIAL | $198,000 | $15,000 | Not Implemented |
SD0295 # 08 Y:2002 | 08 | 2002 | INSTALL AUTOMATIC PACKING EQUIPMENT | $416,352 | $655,000 | Implemented |
SD0295 # 09 Y:2002 | 09 | 2002 | INSTALL AUTOMATIC PACKING EQUIPMENT | $5,965 | $3,500 | Not Implemented |
SD0294 # 01 Y:2002 | 01 | 2002 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $9,512 | $6,000 | Not Implemented |
SD0294 # 02 Y:2002 | 02 | 2002 | ISOLATE HOT OR COLD EQUIPMENT | $3,123 | $5,200 | Not Implemented |
SD0294 # 03 Y:2002 | 03 | 2002 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $4,969 | $2,000 | Not Implemented |
SD0294 # 04 Y:2002 | 04 | 2002 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $501 | $20 | Not Implemented |
SD0294 # 05 Y:2002 | 05 | 2002 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $10,904 | $2,000 | Implemented |
SD0293 # 01 Y:2002 | 01 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $42,804 | $52,000 | Implemented |
SD0293 # 02 Y:2002 | 02 | 2002 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $4,322 | $3,700 | Implemented |
SD0293 # 03 Y:2002 | 03 | 2002 | INSTALL OCCUPANCY SENSORS | $5,121 | $1,000 | Implemented |
SD0293 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,238 | $280 | Implemented |
SD0293 # 05 Y:2002 | 05 | 2002 | INSTALL SPECTRAL REFLECTORS / DELAMP | $2,851 | $4,092 | Not Implemented |
SD0293 # 06 Y:2002 | 06 | 2002 | INCREASE USE OF AUTOMATION | $122,000 | $45,000 | Not Implemented |
SD0293 # 07 Y:2002 | 07 | 2002 | PAY UTILITY BILLS ON TIME | $417 | $0 | Not Implemented |
SD0292 # 01 Y:2002 | 01 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,241 | $0 | Implemented |
SD0292 # 02 Y:2002 | 02 | 2002 | INSTALL TIMERS AND/OR THERMOSTATS | $3,815 | $1,000 | Not Implemented |
SD0292 # 03 Y:2002 | 03 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,012 | $200 | Implemented |
SD0292 # 04 Y:2002 | 04 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $19,200 | $2,000 | Implemented |
SD0292 # 05 Y:2002 | 05 | 2002 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $940 | $2,000 | Not Implemented |
SD0292 # 06 Y:2002 | 06 | 2002 | PAY UTILITY BILLS ON TIME | $530 | $0 | Implemented |
SD0291 # 01 Y:2002 | 01 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $30,611 | $48,000 | n/a |
SD0291 # 02 Y:2002 | 02 | 2002 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $324,586 | $870,000 | n/a |
SD0291 # 03 Y:2002 | 03 | 2002 | USE PHOTOCELL CONTROLS | $14,793 | $5,000 | Not Implemented |