Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
177
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TA0024 # 02 Y:2002 | 02 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,600 | $550 | Implemented |
TA0024 # 03 Y:2002 | 03 | 2002 | CLEAN LINES WITH "PIGS" INSTEAD OF SOLVENTS / SOLUTIONS | $4,915 | $750 | Not Implemented |
TA0024 # 04 Y:2002 | 04 | 2002 | INSULATE BARE EQUIPMENT | $2,680 | $635 | Implemented |
TA0024 # 05 Y:2002 | 05 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,290 | $440 | Implemented |
TA0024 # 06 Y:2002 | 06 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,070 | $700 | Implemented |
TA0024 # 07 Y:2002 | 07 | 2002 | USE SYNTHETIC LUBRICANT | $858 | $0 | Implemented |
TA0024 # 08 Y:2002 | 08 | 2002 | DISCONNECT BALLASTS | $660 | $675 | Not Implemented |
TA0024 # 09 Y:2002 | 09 | 2002 | INSTALL OCCUPANCY SENSORS | $560 | $150 | Implemented |
TA0024 # 10 Y:2002 | 10 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $315 | $640 | Implemented |
TA0024 # 11 Y:2002 | 11 | 2002 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $200 | $0 | Not Implemented |
TA0023 # 01 Y:2002 | 01 | 2002 | PAY UTILITY BILLS ON TIME | $5,506 | $0 | Implemented |
TA0023 # 02 Y:2002 | 02 | 2002 | USE SYNTHETIC LUBRICANT | $3,150 | $0 | Not Implemented |
TA0023 # 03 Y:2002 | 03 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,150 | $0 | Not Implemented |
TA0023 # 04 Y:2002 | 04 | 2002 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $270 | $0 | Implemented |
TA0023 # 05 Y:2002 | 05 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $260 | $468 | Implemented |
TA0022 # 01 Y:2002 | 01 | 2002 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $16,833 | $0 | Implemented |
TA0022 # 02 Y:2002 | 02 | 2002 | PAY UTILITY BILLS ON TIME | $1,006 | $0 | Implemented |
TA0022 # 03 Y:2002 | 03 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $790 | $160 | Implemented |
TA0022 # 04 Y:2002 | 04 | 2002 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $660 | $0 | Implemented |
TA0022 # 05 Y:2002 | 05 | 2002 | INSTALL STORM WINDOWS AND DOORS | $345 | $481 | Not Implemented |
TA0022 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $117 | $220 | Implemented |
TA0021 # 01 Y:2002 | 01 | 2002 | INSTALL / REPAIR INSULATION ON STEAM LINES | $11,450 | $5,883 | Implemented |
TA0021 # 02 Y:2002 | 02 | 2002 | INCREASE AMOUNT OF CONDENSATE RETURNED | $9,736 | $19,010 | Not Implemented |
TA0021 # 03 Y:2002 | 03 | 2002 | REPAIR AND ELIMINATE STEAM LEAKS | $6,110 | $190 | Implemented |
TA0021 # 04 Y:2002 | 04 | 2002 | INSULATE BARE EQUIPMENT | $864 | $504 | Implemented |