Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,799
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0293 # 14 Y:2002 | 14 | 2002 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $133,295 | $97,500 | n/a |
UF0293 # 15 Y:2002 | 15 | 2002 | $4,941 | $5,000 | n/a | |
UF0293 # 16 Y:2002 | 16 | 2002 | $2,808 | $864 | n/a | |
UF0293 # 17 Y:2002 | 17 | 2002 | $10,000 | $752 | n/a | |
UF0292 # 01 Y:2002 | 01 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,946 | $24,472 | Implemented |
UF0292 # 02 Y:2002 | 02 | 2002 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $7,392 | $6,547 | Implemented |
UF0292 # 03 Y:2002 | 03 | 2002 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $4,788 | $50 | Implemented |
UF0292 # 04 Y:2002 | 04 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,347 | $350 | Implemented |
UF0292 # 05 Y:2002 | 05 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $587 | $0 | Implemented |
UF0292 # 06 Y:2002 | 06 | 2002 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $46,032 | $4,000 | Implemented |
UF0292 # 07 Y:2002 | 07 | 2002 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $468 | $0 | Implemented |
UF0292 # 08 Y:2002 | 08 | 2002 | $2,808 | $876 | Not Implemented | |
UF0292 # 09 Y:2002 | 09 | 2002 | $11,250 | $24,938 | Implemented | |
UF0292 # 10 Y:2002 | 10 | 2002 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $140,438 | $39,000 | Implemented |
UF0291 # 01 Y:2002 | 01 | 2002 | $1,755 | $1,050 | Implemented | |
UF0291 # 02 Y:2002 | 02 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $4,427 | $192 | Not Implemented |
UF0291 # 03 Y:2002 | 03 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,917 | $6,752 | Implemented |
UF0291 # 04 Y:2002 | 04 | 2002 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $22,067 | $40,280 | Implemented |
UF0291 # 05 Y:2002 | 05 | 2002 | REPAIR AND ELIMINATE STEAM LEAKS | $1,124 | $450 | Implemented |
UF0291 # 06 Y:2002 | 06 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,424 | $490 | Implemented |
UF0291 # 07 Y:2002 | 07 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $15,235 | $25,190 | Implemented |
UF0291 # 08 Y:2002 | 08 | 2002 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $17,341 | $2,600 | Not Implemented |
UF0291 # 09 Y:2002 | 09 | 2002 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $10,394 | $20,000 | Not Implemented |
UF0291 # 10 Y:2002 | 10 | 2002 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $16,158 | $0 | Not Implemented |
UF0291 # 11 Y:2002 | 11 | 2002 | MOVE BOILER TO MORE EFFICIENT LOCATION | $4,387 | $0 | Implemented |