Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,298
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0449 # 04 Y:2003 | 04 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $16,308 | $2,000 | Not Implemented |
WI0449 # 05 Y:2003 | 05 | 2003 | USE FILTER AND DRYING OVEN TO REDUCE SLUDGE VOLUME | $5,783 | $15,000 | Not Implemented |
WI0449 # 06 Y:2003 | 06 | 2003 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $5,589 | $0 | Not Implemented |
WI0449 # 07 Y:2003 | 07 | 2003 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $2,048 | $3,500 | Not Implemented |
WI0449 # 08 Y:2003 | 08 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $905 | $640 | Not Implemented |
WI0448 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,587 | $13,005 | Implemented |
WI0448 # 02 Y:2003 | 02 | 2003 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $3,564 | $4,300 | Not Implemented |
WI0448 # 03 Y:2003 | 03 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,434 | $1,918 | Not Implemented |
WI0448 # 04 Y:2003 | 04 | 2003 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,870 | $5,000 | Not Implemented |
WI0448 # 05 Y:2003 | 05 | 2003 | INSTALL TIMERS AND/OR THERMOSTATS | $1,558 | $1,200 | Not Implemented |
WI0448 # 06 Y:2003 | 06 | 2003 | ADJUST BURNERS FOR EFFICIENT OPERATION | $962 | $500 | Not Implemented |
WI0448 # 07 Y:2003 | 07 | 2003 | INSTALL OCCUPANCY SENSORS | $610 | $300 | Implemented |
WI0448 # 08 Y:2003 | 08 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $509 | $1,280 | Not Implemented |
WI0447 # 01 Y:2003 | 01 | 2003 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $62,019 | $150,000 | Not Implemented |
WI0447 # 02 Y:2003 | 02 | 2003 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $6,058 | $4,500 | Implemented |
WI0447 # 03 Y:2003 | 03 | 2003 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $2,071 | $2,000 | Not Implemented |
WI0447 # 04 Y:2003 | 04 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $381 | $740 | Not Implemented |
WI0447 # 05 Y:2003 | 05 | 2003 | INSTALL OCCUPANCY SENSORS | $1,938 | $2,600 | Implemented |
WI0446 # 01 Y:2003 | 01 | 2003 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $20,491 | $40,000 | Implemented |
WI0446 # 02 Y:2003 | 02 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,813 | $15,675 | n/a |
WI0446 # 03 Y:2003 | 03 | 2003 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,528 | $500 | Implemented |
WI0446 # 04 Y:2003 | 04 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,093 | $1,359 | Implemented |
WI0446 # 05 Y:2003 | 05 | 2003 | UPGRADE CONTROLS ON COMPRESSORS | $1,214 | $3,500 | Not Implemented |
WI0446 # 06 Y:2003 | 06 | 2003 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $945 | $740 | Implemented |
WI0446 # 07 Y:2003 | 07 | 2003 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $452 | $400 | Not Implemented |