Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,142
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0295 # 04 Y:1989 | 04 | 1989 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $1,301 | $150 | Implemented |
KU0295 # 05 Y:1989 | 05 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,066 | $0 | Implemented |
KU0295 # 08 Y:1989 | 08 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,182 | $500 | Implemented |
KU0294 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $903 | $472 | Implemented |
KU0294 # 04 Y:1989 | 04 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,153 | $4,100 | Implemented |
KU0294 # 05 Y:1989 | 05 | 1989 | INSULATE BARE EQUIPMENT | $1,104 | $600 | Implemented |
KU0294 # 06 Y:1989 | 06 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $526 | $200 | Implemented |
KU0294 # 07 Y:1989 | 07 | 1989 | TURN OFF EQUIPMENT WHEN NOT IN USE | $579 | $0 | Implemented |
KU0286 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,513 | $6,446 | Implemented |
KU0286 # 02 Y:1989 | 02 | 1989 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $235 | $0 | Implemented |
KU0286 # 03 Y:1989 | 03 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,139 | $500 | Implemented |
KU0286 # 04 Y:1989 | 04 | 1989 | INSTALL AUTOMATIC STACK DAMPER | $6,820 | $5,625 | Implemented |
KU0286 # 05 Y:1989 | 05 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,698 | $1,800 | Implemented |
KU0286 # 06 Y:1989 | 06 | 1989 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $14,815 | $20,000 | Implemented |
KU0286 # 07 Y:1989 | 07 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $204 | $250 | Implemented |
KU0287 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,271 | $400 | Implemented |
KU0282 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,973 | $270 | Implemented |
KU0282 # 04 Y:1989 | 04 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $2,121 | $670 | Implemented |
KU0282 # 06 Y:1989 | 06 | 1989 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $319 | $82 | Implemented |
KU0282 # 07 Y:1989 | 07 | 1989 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $329 | $50 | Implemented |
KU0282 # 08 Y:1989 | 08 | 1989 | REDUCE OR ELIMINATE WASTE | $800 | $50 | Implemented |
KU0281 # 01 Y:1989 | 01 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,927 | $4,000 | Implemented |
KU0281 # 02 Y:1989 | 02 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $960 | $1,500 | Implemented |
KU0281 # 03 Y:1989 | 03 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $512 | $214 | Implemented |
KU0281 # 04 Y:1989 | 04 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $6,778 | $9,550 | Implemented |