Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,628
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0138 # 02 Y:1984 | 02 | 1984 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $9,379 | $15,000 | Implemented |
UD0132 # 02 Y:1984 | 02 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,478 | $500 | Implemented |
UD0132 # 03 Y:1984 | 03 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $698 | $1,436 | Implemented |
UD0132 # 04 Y:1984 | 04 | 1984 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $823 | $0 | Implemented |
UD0133 # 03 Y:1984 | 03 | 1984 | INSTALL SET-BACK TIMERS | $1,754 | $1,271 | Implemented |
UD0133 # 04 Y:1984 | 04 | 1984 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $3,629 | $6,000 | Implemented |
UD0127 # 01 Y:1984 | 01 | 1984 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,316 | $1,000 | Implemented |
UD0127 # 02 Y:1984 | 02 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,943 | $10,634 | Implemented |
UD0127 # 03 Y:1984 | 03 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $6,348 | $15,950 | Implemented |
UD0127 # 04 Y:1984 | 04 | 1984 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $79 | $83 | Implemented |
UD0131 # 01 Y:1984 | 01 | 1984 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $7,171 | $0 | Implemented |
UD0131 # 02 Y:1984 | 02 | 1984 | REDUCE GLAZED AREAS IN BUILDINGS | $17,464 | $50,000 | Implemented |
UD0131 # 03 Y:1984 | 03 | 1984 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $3,070 | $8,000 | Implemented |
UD0131 # 04 Y:1984 | 04 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,853 | $800 | Implemented |
UD0131 # 05 Y:1984 | 05 | 1984 | USE HOT PROCESS FLUIDS TO PREHEAT INCOMING PROCESS FLUIDS | $2,576 | $4,000 | Implemented |
UD0131 # 06 Y:1984 | 06 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,453 | $20,000 | Implemented |
UD0125 # 01 Y:1984 | 01 | 1984 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $11,583 | $11,079 | Implemented |
UD0125 # 02 Y:1984 | 02 | 1984 | COVER OPEN TANKS | $1,611 | $1,080 | Implemented |
UD0125 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,474 | $5,156 | Implemented |
UD0126 # 01 Y:1984 | 01 | 1984 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,095 | $1,000 | Implemented |
UD0126 # 02 Y:1984 | 02 | 1984 | DISCONNECT BALLASTS | $1,386 | $2,310 | Implemented |
UD0126 # 03 Y:1984 | 03 | 1984 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,630 | $0 | Implemented |
UD0128 # 01 Y:1984 | 01 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,370 | $0 | Implemented |
UD0128 # 02 Y:1984 | 02 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,748 | $9,000 | Implemented |
UD0122 # 01 Y:1984 | 01 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $8,037 | $2,800 | Implemented |