Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,643
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0189 # 10 Y:1996 | 10 | 1996 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $96 | $100 | Implemented |
AS0188 # 01 Y:1996 | 01 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $11,373 | $21,500 | Implemented |
AS0188 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $9,900 | $13,282 | Implemented |
AS0188 # 04 Y:1996 | 04 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,409 | $9,450 | Implemented |
AS0188 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,780 | $17,184 | Implemented |
AS0188 # 07 Y:1996 | 07 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $280 | $450 | Implemented |
AS0187 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,717 | $6,352 | Implemented |
AS0187 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,089 | $1,421 | Implemented |
AS0187 # 05 Y:1996 | 05 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,677 | $0 | Implemented |
AS0187 # 06 Y:1996 | 06 | 1996 | TREAT AND REUSE RINSE WATERS | $17,828 | $1,300 | Implemented |
AS0186 # 01 Y:1996 | 01 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $12,586 | $16,140 | Implemented |
AS0186 # 02 Y:1996 | 02 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,274 | $5,945 | Implemented |
AS0186 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $13,734 | $7,000 | Implemented |
AS0186 # 04 Y:1996 | 04 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,738 | $0 | Implemented |
AS0186 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,675 | $2,086 | Implemented |
AS0186 # 06 Y:1996 | 06 | 1996 | INSTALL OCCUPANCY SENSORS | $712 | $525 | Implemented |
AS0186 # 07 Y:1996 | 07 | 1996 | METER WASTE WATER | $8,798 | $5,000 | Implemented |
AS0186 # 08 Y:1996 | 08 | 1996 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $465 | $0 | Implemented |
AS0185 # 01 Y:1996 | 01 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,866 | $0 | Implemented |
AS0185 # 02 Y:1996 | 02 | 1996 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,309 | $255 | Implemented |
AS0185 # 03 Y:1996 | 03 | 1996 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $416 | $120 | Implemented |
AS0185 # 04 Y:1996 | 04 | 1996 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $882 | $100 | Implemented |
AS0185 # 05 Y:1996 | 05 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,378 | $1,938 | Implemented |
AS0185 # 08 Y:1996 | 08 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $103 | $128 | Implemented |
AS0185 # 10 Y:1996 | 10 | 1996 | IMPROVE HANDLING PRACTICES | $3,909 | $1,500 | Implemented |