Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,627
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0262 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,250 | $90 | Implemented |
CO0262 # 05 Y:1993 | 05 | 1993 | INSULATE BARE EQUIPMENT | $640 | $240 | Implemented |
CO0262 # 06 Y:1993 | 06 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $310 | $200 | Implemented |
CO0262 # 10 Y:1993 | 10 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $190 | $420 | Implemented |
CO0261 # 01 Y:1993 | 01 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $740 | $80 | Implemented |
CO0261 # 02 Y:1993 | 02 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $2,250 | $2,250 | Implemented |
CO0261 # 05 Y:1993 | 05 | 1993 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $230 | $280 | Implemented |
CO0260 # 01 Y:1992 | 01 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,200 | $1,000 | Implemented |
CO0260 # 02 Y:1992 | 02 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,880 | $500 | Implemented |
CO0260 # 03 Y:1992 | 03 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,820 | $310 | Implemented |
CO0260 # 04 Y:1992 | 04 | 1992 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $8,920 | $8,750 | Implemented |
CO0260 # 05 Y:1992 | 05 | 1992 | COVER OPEN TANKS | $13,870 | $4,000 | Implemented |
CO0260 # 06 Y:1992 | 06 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $176,510 | $40,000 | Implemented |
CO0260 # 07 Y:1992 | 07 | 1992 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $84,970 | $120,000 | Implemented |
CO0260 # 08 Y:1992 | 08 | 1992 | INSULATE BARE EQUIPMENT | $1,500 | $700 | Implemented |
CO0260 # 09 Y:1992 | 09 | 1992 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $5,880 | $7,700 | Implemented |
CO0260 # 10 Y:1992 | 10 | 1992 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $300 | $150 | Implemented |
CO0260 # 11 Y:1992 | 11 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $106 | $900 | Implemented |
CO0260 # 12 Y:1992 | 12 | 1992 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $14,750 | $20,280 | Implemented |
CO0260 # 13 Y:1992 | 13 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,130 | $2,870 | Implemented |
CO0260 # 14 Y:1992 | 14 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $820 | $2,610 | Implemented |
CO0259 # 01 Y:1992 | 01 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,620 | $100 | Implemented |
CO0259 # 02 Y:1992 | 02 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,410 | $520 | Implemented |
CO0259 # 03 Y:1992 | 03 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,140 | $990 | Implemented |
CO0259 # 04 Y:1992 | 04 | 1992 | REDUCE VENTILATION AIR | $2,860 | $1,000 | Implemented |