Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,090
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0305 # 01 Y:1987 | 01 | 1987 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $2,479 | $0 | Implemented |
TN0305 # 03 Y:1987 | 03 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,298 | $210 | Implemented |
TN0305 # 06 Y:1987 | 06 | 1987 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,034 | $348 | Implemented |
TN0305 # 07 Y:1987 | 07 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $526 | $120 | Implemented |
TN0300 # 01 Y:1987 | 01 | 1987 | INSTALL / REPAIR INSULATION ON STEAM LINES | $17,707 | $6,612 | Implemented |
TN0300 # 02 Y:1987 | 02 | 1987 | REPAIR AND ELIMINATE STEAM LEAKS | $12,978 | $760 | Implemented |
TN0300 # 03 Y:1987 | 03 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,734 | $0 | Implemented |
TN0300 # 05 Y:1987 | 05 | 1987 | USE MINIMUM STEAM OPERATING PRESSURE | $3,671 | $0 | Implemented |
TN0300 # 06 Y:1987 | 06 | 1987 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $12,750 | $4,240 | Implemented |
TN0300 # 08 Y:1987 | 08 | 1987 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $731 | $107 | Implemented |
TN0302 # 01 Y:1987 | 01 | 1987 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,791 | $6,512 | Implemented |
TN0302 # 02 Y:1987 | 02 | 1987 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,877 | $0 | Implemented |
TN0302 # 03 Y:1987 | 03 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $874 | $150 | Implemented |
TN0302 # 04 Y:1987 | 04 | 1987 | INSTALL SET-BACK TIMERS | $822 | $0 | Implemented |
TN0302 # 05 Y:1987 | 05 | 1987 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $9 | $0 | Implemented |
TN0302 # 06 Y:1987 | 06 | 1987 | INSULATE BARE EQUIPMENT | $197 | $184 | Implemented |
TN0303 # 01 Y:1987 | 01 | 1987 | INSTALL SET-BACK TIMERS | $11,719 | $0 | Implemented |
TN0303 # 02 Y:1987 | 02 | 1987 | INSULATE BARE EQUIPMENT | $7,037 | $1,200 | Implemented |
TN0303 # 03 Y:1987 | 03 | 1987 | INSULATE BARE EQUIPMENT | $1,769 | $1,904 | Implemented |
TN0303 # 04 Y:1987 | 04 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,973 | $780 | Implemented |
TN0303 # 06 Y:1987 | 06 | 1987 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $948 | $3,960 | Implemented |
TN0303 # 08 Y:1987 | 08 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,815 | $720 | Implemented |
TN0303 # 09 Y:1987 | 09 | 1987 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $661 | $348 | Implemented |
TN0303 # 12 Y:1987 | 12 | 1987 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $174,746 | $36,800 | Implemented |
TN0303 # 13 Y:1987 | 13 | 1987 | HEAT WATER WITH EXHAUST HEAT | $15,719 | $26,500 | Implemented |