Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,585

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0073 # 09 Y:1994 09 1994 OPTIMIZE PLANT POWER FACTOR $1,451 $4,140 Implemented
UF0077 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $10,973 $14,637 Implemented
WI0196 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,005 $3,657 Implemented
WI0196 # 03 Y:1994 03 1994 USE PHOTOCELL CONTROLS $1,159 $675 Implemented
WI0196 # 04 Y:1994 04 1994 INSTALL OCCUPANCY SENSORS $626 $225 Implemented
WI0196 # 05 Y:1994 05 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,512 $500 Implemented
WI0196 # 09 Y:1994 09 1994 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $914 $0 Implemented
WV0016 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $838 $1,474 Implemented
WV0016 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $247 $8,480 Implemented
WV0016 # 04 Y:1994 04 1994 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,520 $1,190 Implemented
WV0016 # 06 Y:1994 06 1994 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,528 $900 Implemented
WV0016 # 07 Y:1994 07 1994 INSTALL / REPAIR INSULATION ON STEAM LINES $730 $329 Implemented
WV0016 # 09 Y:1994 09 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $220 $0 Implemented
UF0076 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $935 $112 Implemented
UF0076 # 02 Y:1994 02 1994 INSTALL OCCUPANCY SENSORS $88 $64 Implemented
UF0076 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $104 $80 Implemented
UF0076 # 05 Y:1994 05 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $499 $1,123 Implemented
UF0076 # 06 Y:1994 06 1994 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $891 $2,450 Implemented
MA0291 # 03 Y:1994 03 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,086 $0 Implemented
MA0291 # 04 Y:1994 04 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $586 $0 Implemented
SF0016 # 01 Y:1994 01 1994 OPTIMIZE PLANT POWER FACTOR $24,584 $57,981 Implemented
SF0016 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $39,338 $33,934 Implemented
SF0016 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,487 $6,576 Implemented
SF0016 # 04 Y:1994 04 1994 INSTALL OCCUPANCY SENSORS $5,124 $854 Implemented
SF0016 # 06 Y:1994 06 1994 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $16,290 $0 Implemented