Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,629
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OR0016 # 05 Y:1988 | 05 | 1988 | OPTIMIZE PLANT POWER FACTOR | $1,972 | $4,110 | Not Implemented |
OR0017 # 01 Y:1988 | 01 | 1988 | USE MINIMUM STEAM OPERATING PRESSURE | $326 | $0 | Implemented |
OR0017 # 02 Y:1988 | 02 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $818 | $0 | Not Implemented |
OR0017 # 03 Y:1988 | 03 | 1988 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $2,710 | $0 | Implemented |
OR0017 # 04 Y:1988 | 04 | 1988 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $6,291 | $0 | Implemented |
OR0017 # 05 Y:1988 | 05 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,466 | $300 | Implemented |
OR0017 # 06 Y:1988 | 06 | 1988 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $150 | $76 | Not Implemented |
OR0017 # 07 Y:1988 | 07 | 1988 | RECOVER AND REUSE COOLING WATER | $502 | $320 | Not Implemented |
OR0017 # 08 Y:1988 | 08 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $276 | $298 | Not Implemented |
OR0017 # 09 Y:1988 | 09 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $518 | $997 | Implemented |
RU0016 # 01 Y:1988 | 01 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $22,305 | $15,000 | Implemented |
RU0016 # 02 Y:1988 | 02 | 1988 | IMPROVE LUBRICATION PRACTICES | $3,367 | $1,600 | Implemented |
RU0016 # 03 Y:1988 | 03 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,922 | $1,150 | Implemented |
RU0016 # 04 Y:1988 | 04 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $828 | $500 | Implemented |
RU0016 # 05 Y:1988 | 05 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $999 | $2,000 | Implemented |
RU0017 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,392 | $262 | Implemented |
RU0017 # 02 Y:1988 | 02 | 1988 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $4,029 | $2,200 | Implemented |
RU0017 # 03 Y:1988 | 03 | 1988 | IMPROVE LUBRICATION PRACTICES | $614 | $0 | Not Implemented |
AM0016 # 01 Y:1988 | 01 | 1988 | INSULATE BARE EQUIPMENT | $5,785 | $10,000 | Not Implemented |
AM0016 # 02 Y:1988 | 02 | 1988 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $631 | $0 | Implemented |
AM0016 # 03 Y:1988 | 03 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $412 | $464 | Implemented |
AM0016 # 04 Y:1988 | 04 | 1988 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $478 | $500 | Implemented |
AM0016 # 05 Y:1988 | 05 | 1988 | INSTALL SET-BACK TIMERS | $163 | $0 | Implemented |
AM0016 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $61 | $54 | Implemented |
AM0017 # 01 Y:1988 | 01 | 1988 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $11,970 | $190 | Implemented |