Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,541

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0663 # 04 Y:2003 04 2003 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $36,720 $4,800 Not Implemented
UD0663 # 05 Y:2003 05 2003 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $33,589 $102,000 Not Implemented
UD0663 # 06 Y:2003 06 2003 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $24,572 $0 Not Implemented
UD0663 # 07 Y:2003 07 2003 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,728 $4,941 Not Implemented
UD0663 # 08 Y:2003 08 2003 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,356 $975 Not Implemented
UD0663 # 09 Y:2003 09 2003 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $1,042 $368 Not Implemented
UD0663 # 10 Y:2003 10 2003 COVER OPEN TANKS $760 $1,870 Not Implemented
IC0048 # 01 Y:2002 01 2002 TURN OFF EQUIPMENT WHEN NOT IN USE $7,063 $0 Implemented
IC0048 # 02 Y:2002 02 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $30,279 $10,600 Implemented
IC0048 # 03 Y:2002 03 2002 TURN OFF EQUIPMENT WHEN NOT IN USE $56,765 $35,050 Implemented
IC0048 # 04 Y:2002 04 2002 RECOVER WASTE HEAT FROM EQUIPMENT $71,006 $3,130 Not Implemented
IC0048 # 05 Y:2002 05 2002 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $40,640 $108,000 Not Implemented
IC0048 # 06 Y:2002 06 2002 RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR $472,157 $1,500,000 Not Implemented
IC0048 # 07 Y:2002 07 2002 RECOVER WASTE HEAT FROM EQUIPMENT $17,986 $0 Implemented
IC0048 # 08 Y:2002 08 2002 REDUCE OR ELIMINATE WASTE $249,587 $207,024 Not Implemented
IC0048 # 09 Y:2002 09 2002 $364,437 $18,654 Not Implemented
IC0040 # 01 Y:2002 01 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,248 $47,200 Not Implemented
IC0040 # 02 Y:2002 02 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,379 $23,767 Not Implemented
IC0040 # 03 Y:2002 03 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $13,978 $3,100 Implemented
IC0040 # 04 Y:2002 04 2002 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,817 $0 Implemented
IC0040 # 05 Y:2002 05 2002 TURN OFF EQUIPMENT WHEN NOT IN USE $5,341 $0 Not Implemented
IC0040 # 06 Y:2002 06 2002 TURN OFF EQUIPMENT WHEN NOT IN USE $3,923 $5,500 Implemented
IC0040 # 07 Y:2002 07 2002 ADJUST BURNERS FOR EFFICIENT OPERATION $10,651 $2,640 Not Implemented
IC0040 # 08 Y:2002 08 2002 COVER OPEN TANKS $18,222 $3,181 Not Implemented
IC0040 # 09 Y:2002 09 2002 INSULATE BARE EQUIPMENT $1,281 $756 Not Implemented