Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,942
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0890 # 11 Y:2013 | 11 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $565,879 | $1,157,500 | Not Implemented |
UD0890 # 12 Y:2013 | 12 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $19,159 | $0 | Not Implemented |
UD0889 # 01 Y:2013 | 01 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,100 | $0 | Implemented |
UD0889 # 02 Y:2013 | 02 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $654 | $460 | Implemented |
UD0889 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,448 | $1,000 | Not Implemented |
UD0889 # 04 Y:2013 | 04 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,551 | $3,500 | Not Implemented |
UD0889 # 05 Y:2013 | 05 | 2013 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,355 | $2,000 | Not Implemented |
UD0889 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,219 | $7,254 | Not Implemented |
UD0889 # 07 Y:2013 | 07 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,401 | $9,000 | Not Implemented |
UD0889 # 08 Y:2013 | 08 | 2013 | INSTALL OCCUPANCY SENSORS | $1,290 | $1,400 | Not Implemented |
UD0887 # 01 Y:2013 | 01 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,553 | $50 | Implemented |
UD0887 # 02 Y:2013 | 02 | 2013 | REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES | $1,438 | $0 | Implemented |
UD0887 # 03 Y:2013 | 03 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $497 | $500 | Implemented |
UD0887 # 04 Y:2013 | 04 | 2013 | INSTALL SPECTRAL REFLECTORS / DELAMP | $8,763 | $2,075 | Implemented |
UD0887 # 05 Y:2013 | 05 | 2013 | ADD AREA LIGHTING SWITCHES | $3,141 | $350 | Not Implemented |
UD0887 # 06 Y:2013 | 06 | 2013 | ADD AREA LIGHTING SWITCHES | $594 | $350 | Implemented |
UD0887 # 07 Y:2013 | 07 | 2013 | OPTIMIZE PLANT POWER FACTOR | $19,173 | $10,000 | Not Implemented |
UD0887 # 08 Y:2013 | 08 | 2013 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $10,244 | $0 | Not Implemented |
UD0887 # 09 Y:2013 | 09 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,136 | $4,000 | Not Implemented |
UD0887 # 10 Y:2013 | 10 | 2013 | USE HEAT IN FLUE GASES TO PREHEAT PRODUCTS OR MATERIALS | $187 | $300 | Not Implemented |
UD0887 # 11 Y:2013 | 11 | 2013 | DEVELOP A REPAIR/REPLACE POLICY | $2,637 | $3,420 | Implemented |
UD0887 # 12 Y:2013 | 12 | 2013 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $500 | $0 | Not Implemented |
UD0887 # 13 Y:2013 | 13 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $383 | $0 | Implemented |
UD0886 # 01 Y:2013 | 01 | 2013 | MINIMIZE WATER USAGE | $32,244 | $1,000 | Not Implemented |
UD0886 # 02 Y:2013 | 02 | 2013 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $4,317 | $1,000 | Not Implemented |