IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,777

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WI0147 # 05 Y:1992 05 1992 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,513 $500 Implemented
WI0147 # 06 Y:1992 06 1992 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,444 $0 Not Implemented
WI0147 # 07 Y:1992 07 1992 INSTALL TIMERS AND/OR THERMOSTATS $555 $400 Implemented
WI0147 # 08 Y:1992 08 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,386 $3,640 Not Implemented
WI0148 # 01 Y:1992 01 1992 INSTALL TIMERS AND/OR THERMOSTATS $2,857 $400 Implemented
WI0148 # 02 Y:1992 02 1992 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,889 $0 Not Implemented
WI0148 # 03 Y:1992 03 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $110 $2 Implemented
WI0148 # 04 Y:1992 04 1992 INSTALL SET-BACK TIMERS $532 $400 Not Implemented
WI0148 # 05 Y:1992 05 1992 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $97 $75 Not Implemented
WI0148 # 06 Y:1992 06 1992 INSTALL AUTOMATIC STACK DAMPER $547 $700 Not Implemented
WI0148 # 07 Y:1992 07 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $134 $640 Implemented
WI0148 # 08 Y:1992 08 1992 SHUT OFF PILOTS IN STANDBY EQUIPMENT $75 $0 Not Implemented
WI0149 # 01 Y:1992 01 1992 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $23,441 $0 Not Implemented
WI0149 # 02 Y:1992 02 1992 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $2,795 $5,000 Not Implemented
WI0149 # 03 Y:1992 03 1992 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $10,128 $30,000 Implemented
WI0149 # 04 Y:1992 04 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,770 $7 Implemented
WI0149 # 05 Y:1992 05 1992 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $5,137 $4,550 Not Implemented
WI0149 # 06 Y:1992 06 1992 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $2,140 $250 Implemented
WI0149 # 07 Y:1992 07 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,314 $800 Not Implemented
WI0149 # 08 Y:1992 08 1992 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $1,641 $1,000 Not Implemented
WI0149 # 09 Y:1992 09 1992 INSULATE BARE EQUIPMENT $1,139 $189 Implemented
WI0149 # 10 Y:1992 10 1992 INSULATE BARE EQUIPMENT $460 $295 Implemented
GT0463 # 01 Y:1992 01 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,813 $104,880 Implemented
GT0463 # 02 Y:1992 02 1992 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $7,700 $2,000 Implemented
GT0463 # 03 Y:1992 03 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,371 $7,200 Implemented