IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,314

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AS0199 # 05 Y:1997 05 1997 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $10,117 $7,000 Not Implemented
AS0199 # 06 Y:1997 06 1997 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,411 $3,015 Not Implemented
AS0199 # 07 Y:1997 07 1997 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,995 $13,000 Not Implemented
AS0199 # 08 Y:1997 08 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,635 $3,183 Implemented
AS0199 # 09 Y:1997 09 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $396 $570 Implemented
AS0199 # 10 Y:1997 10 1997 INSTALL SKYLIGHTS $1,207 $1,200 Not Implemented
AS0199 # 11 Y:1997 11 1997 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,037 $0 Implemented
AS0199 # 12 Y:1997 12 1997 INSTALL OCCUPANCY SENSORS $1,492 $2,250 Not Implemented
AS0199 # 13 Y:1997 13 1997 RECYCLE NONFERROUS DUST $176 $0 Not Implemented
AS0199 # 14 Y:1997 14 1997 CONDENSE OPERATION INTO ONE BUILDING $205,047 $15,000 Not Implemented
AS0198 # 01 Y:1997 01 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,972 $5,673 Implemented
AS0198 # 02 Y:1997 02 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,563 $7,630 Implemented
AS0198 # 03 Y:1997 03 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,181 $0 Implemented
AS0198 # 04 Y:1997 04 1997 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $763 $2,805 Not Implemented
AS0198 # 05 Y:1997 05 1997 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $648 $700 Not Implemented
AS0198 # 06 Y:1997 06 1997 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $609 $0 Implemented
AS0198 # 07 Y:1997 07 1997 INSTALL OCCUPANCY SENSORS $280 $225 Implemented
AS0198 # 08 Y:1997 08 1997 USE SYNTHETIC LUBRICANT $201 $295 Implemented
AS0198 # 09 Y:1997 09 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $144 $90 Implemented
AS0198 # 10 Y:1997 10 1997 INSTALL TIMERS AND/OR THERMOSTATS $135 $320 Implemented
AS0198 # 11 Y:1997 11 1997 CONTRACT A WOOD PALLET RECYCLING COMPANY $360 $0 Not Implemented
AS0198 # 12 Y:1997 12 1997 INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE $252 $0 Not Implemented
AS0198 # 13 Y:1997 13 1997 PAY BILLS ON TIME TO AVOID LATE FEES $761 $0 Implemented
AS0197 # 01 Y:1997 01 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,219 $0 Not Implemented
AS0197 # 02 Y:1997 02 1997 USE SYNTHETIC LUBRICANT $2,789 $1,625 Implemented