Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,032
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0175 # 07 Y:1985 | 07 | 1985 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $313 | $1,500 | Not Implemented |
KU0175 # 08 Y:1985 | 08 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $191 | $0 | Implemented |
KU0175 # 09 Y:1985 | 09 | 1985 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $175 | $0 | Implemented |
KU0176 # 01 Y:1985 | 01 | 1985 | INSTALL AUTOMATIC STACK DAMPER | $1,232 | $1,875 | Not Implemented |
KU0176 # 02 Y:1985 | 02 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,562 | $1,540 | Implemented |
KU0176 # 03 Y:1985 | 03 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $618 | $1,200 | Not Implemented |
KU0176 # 04 Y:1985 | 04 | 1985 | REDUCE VENTILATION AIR | $227 | $200 | Not Implemented |
KU0176 # 05 Y:1985 | 05 | 1985 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $203 | $0 | Implemented |
KU0176 # 06 Y:1985 | 06 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $188 | $60 | Implemented |
KU0177 # 01 Y:1985 | 01 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $972 | $0 | Implemented |
KU0177 # 02 Y:1985 | 02 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $4,851 | $2,700 | Implemented |
KU0177 # 03 Y:1985 | 03 | 1985 | INSTALL AUTOMATIC STACK DAMPER | $1,700 | $1,950 | Not Implemented |
KU0177 # 04 Y:1985 | 04 | 1985 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $110 | $0 | Implemented |
KU0177 # 05 Y:1985 | 05 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $754 | $200 | Implemented |
KU0177 # 06 Y:1985 | 06 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,218 | $700 | Implemented |
KU0177 # 07 Y:1985 | 07 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $174 | $10 | Not Implemented |
KU0177 # 08 Y:1985 | 08 | 1985 | OPTIMIZE PLANT POWER FACTOR | $1,714 | $4,000 | Implemented |
KU0177 # 09 Y:1985 | 09 | 1985 | IMPROVE LUBRICATION PRACTICES | $232 | $200 | Not Implemented |
KU0177 # 10 Y:1985 | 10 | 1985 | ADD AIR SHIELDS TO TRUCKS TO INCREASE FUEL MILEAGE | $721 | $0 | Implemented |
KU0179 # 01 Y:1985 | 01 | 1985 | INSTALL TIMERS AND/OR THERMOSTATS | $1,642 | $500 | Implemented |
KU0179 # 02 Y:1985 | 02 | 1985 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $1,693 | $764 | Not Implemented |
KU0179 # 03 Y:1985 | 03 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $990 | $1,450 | Implemented |
KU0179 # 04 Y:1985 | 04 | 1985 | USE OPTIMUM THICKNESS INSULATION | $730 | $1,138 | Not Implemented |
KU0179 # 05 Y:1985 | 05 | 1985 | COVER OPEN TANKS | $279 | $60 | Implemented |
KU0179 # 06 Y:1985 | 06 | 1985 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $174 | $0 | Implemented |