Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,314
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0181 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,603 | $340 | Not Implemented |
AS0181 # 03 Y:1996 | 03 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,132 | $11,508 | Not Implemented |
AS0181 # 04 Y:1996 | 04 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $455 | $0 | Not Implemented |
AS0181 # 05 Y:1996 | 05 | 1996 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $496 | $0 | Not Implemented |
AS0181 # 06 Y:1996 | 06 | 1996 | TURN OFF EQUIPMENT WHEN NOT IN USE | $272 | $0 | Not Implemented |
AS0181 # 07 Y:1996 | 07 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,995 | $5,202 | Not Implemented |
AS0181 # 08 Y:1996 | 08 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,786 | $11,732 | Not Implemented |
AS0181 # 09 Y:1996 | 09 | 1996 | INSTALL OCCUPANCY SENSORS | $595 | $1,575 | Not Implemented |
AS0181 # 10 Y:1996 | 10 | 1996 | MINIMIZE WATER USAGE | $979 | $200 | Not Implemented |
AS0180 # 01 Y:1996 | 01 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,604 | $0 | Not Implemented |
AS0180 # 02 Y:1996 | 02 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $18,978 | $14,977 | Implemented |
AS0180 # 03 Y:1996 | 03 | 1996 | INSTALL OCCUPANCY SENSORS | $2,295 | $1,350 | Not Implemented |
AS0180 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,307 | $9,177 | Not Implemented |
AS0180 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,240 | $5,343 | Not Implemented |
AS0180 # 06 Y:1996 | 06 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $63,244 | $50,000 | Implemented |
AS0180 # 07 Y:1996 | 07 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,003 | $0 | Not Implemented |
AS0180 # 08 Y:1996 | 08 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $391 | $320 | Not Implemented |
AS0180 # 09 Y:1996 | 09 | 1996 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $1,648 | $30 | Implemented |
AS0180 # 10 Y:1996 | 10 | 1996 | USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE | $330 | $30 | Implemented |
AS0180 # 11 Y:1996 | 11 | 1996 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $1,041 | $1,780 | Implemented |
AS0179 # 01 Y:1996 | 01 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,521 | $21,600 | Implemented |
AS0179 # 02 Y:1996 | 02 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $10,187 | $7,700 | Not Implemented |
AS0179 # 03 Y:1996 | 03 | 1996 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $8,307 | $12,000 | Not Implemented |
AS0179 # 04 Y:1996 | 04 | 1996 | INSULATE BARE EQUIPMENT | $1,590 | $150 | Implemented |
AS0179 # 05 Y:1996 | 05 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $25,441 | $15,981 | Implemented |