Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,474
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0439 # 02 Y:1994 | 02 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,009 | $0 | Not Implemented |
UD0439 # 03 Y:1994 | 03 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,183 | $1,500 | Not Implemented |
UD0439 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,763 | $12,575 | Not Implemented |
UD0433 # 01 Y:1994 | 01 | 1994 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $6,342 | $20,000 | Not Implemented |
UD0433 # 02 Y:1994 | 02 | 1994 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $4,410 | $0 | Implemented |
UD0433 # 03 Y:1994 | 03 | 1994 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $2,059 | $300 | Implemented |
UD0433 # 04 Y:1994 | 04 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,093 | $2,500 | Not Implemented |
UD0433 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,315 | $1,950 | Implemented |
UM0005 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,350 | $7,970 | Implemented |
UM0005 # 02 Y:1994 | 02 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $970 | $500 | Implemented |
UM0005 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,410 | $9,428 | Implemented |
UM0005 # 04 Y:1994 | 04 | 1994 | COVER OPEN TANKS | $6,181 | $4,762 | Not Implemented |
UM0005 # 05 Y:1994 | 05 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $986 | $600 | Implemented |
UM0005 # 06 Y:1994 | 06 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $561 | $200 | Implemented |
UM0005 # 07 Y:1994 | 07 | 1994 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $17,300 | $6,600 | Implemented |
UM0005 # 08 Y:1994 | 08 | 1994 | INSTALL WASTE HEAT BOILER TO PROVIDE DIRECT POWER | $40,230 | $34,000 | Implemented |
SD0088 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,963 | $4,300 | Implemented |
SD0088 # 02 Y:1994 | 02 | 1994 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $6,722 | $200 | Implemented |
SD0088 # 03 Y:1994 | 03 | 1994 | INSULATE BARE EQUIPMENT | $376 | $235 | Implemented |
SD0088 # 04 Y:1994 | 04 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,853 | $150 | Implemented |
SD0088 # 05 Y:1994 | 05 | 1994 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $117,014 | $245,000 | Implemented |
SD0088 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $40,436 | $95,019 | Implemented |
SD0088 # 07 Y:1994 | 07 | 1994 | INSTALL SPECTRAL REFLECTORS / DELAMP | $39,115 | $43,220 | Implemented |
SD0088 # 08 Y:1994 | 08 | 1994 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $4,548 | $810 | Implemented |
MS0002 # 01 Y:1994 | 01 | 1994 | OPTIMIZE PLANT POWER FACTOR | $7,089 | $9,000 | Not Implemented |