Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,230
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LL0341 # 01 Y:2011 | 01 | 2011 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $10,506 | $1,800 | Not Implemented |
LL0341 # 02 Y:2011 | 02 | 2011 | INSTALL OCCUPANCY SENSORS | $2,820 | $6,447 | Not Implemented |
LL0341 # 03 Y:2011 | 03 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $2,760 | $3,072 | Implemented |
LL0341 # 04 Y:2011 | 04 | 2011 | COMBINE UTILITY METERS | $2,504 | $210 | Not Implemented |
LL0341 # 05 Y:2011 | 05 | 2011 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $1,581 | $150 | Implemented |
LL0341 # 06 Y:2011 | 06 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,071 | $1,290 | Not Implemented |
LL0341 # 07 Y:2011 | 07 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $890 | $525 | Not Implemented |
LL0341 # 08 Y:2011 | 08 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $90 | $80 | Not Implemented |
LL0341 # 09 Y:2011 | 09 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $51 | $30 | Not Implemented |
LL0341 # 10 Y:2011 | 10 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $90 | $80 | Not Implemented |
LL0341 # 11 Y:2011 | 11 | 2011 | INSULATE BARE EQUIPMENT | $269 | $366 | Implemented |
IA0461 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,898 | $1,649 | Not Implemented |
IA0461 # 02 Y:2011 | 02 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,749 | $12,616 | Not Implemented |
IA0461 # 03 Y:2011 | 03 | 2011 | INSTALL OCCUPANCY SENSORS | $2,492 | $1,078 | Not Implemented |
IA0461 # 04 Y:2011 | 04 | 2011 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,625 | $40 | Not Implemented |
IA0461 # 05 Y:2011 | 05 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $10,733 | $5,500 | Not Implemented |
IA0461 # 06 Y:2011 | 06 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,668 | $200 | Not Implemented |
IA0461 # 07 Y:2011 | 07 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $430 | $240 | Not Implemented |
IA0461 # 08 Y:2011 | 08 | 2011 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $384 | $20 | Not Implemented |
IA0461 # 09 Y:2011 | 09 | 2011 | RECOVER WASTE HEAT FROM EQUIPMENT | $13,101 | $5,000 | Not Implemented |
AM0593 # 01 Y:2011 | 01 | 2011 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $106,400 | $0 | Not Implemented |
AM0593 # 02 Y:2011 | 02 | 2011 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $19,900 | $2,600 | Not Implemented |
AM0593 # 03 Y:2011 | 03 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,900 | $1,000 | Implemented |
AM0593 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,600 | $6,900 | Implemented |
AM0593 # 05 Y:2011 | 05 | 2011 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $4,260 | $500 | Implemented |