IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,533

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TA0092 # 08 Y:2005 08 2005 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $250 $0 Not Implemented
WV0312 # 01 Y:2005 01 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $15,023 $6,435 Not Implemented
WV0312 # 02 Y:2005 02 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $14,049 $18,750 Implemented
WV0312 # 03 Y:2005 03 2005 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $14,013 $9,600 Not Implemented
WV0312 # 04 Y:2005 04 2005 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $6,107 $2,970 Implemented
WV0312 # 05 Y:2005 05 2005 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $5,641 $7,480 Not Implemented
WV0312 # 06 Y:2005 06 2005 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,708 $250 Implemented
WV0312 # 07 Y:2005 07 2005 DEVELOP A REPAIR/REPLACE POLICY $3,672 $413 Not Implemented
WV0312 # 08 Y:2005 08 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,210 $4,800 Implemented
WV0312 # 09 Y:2005 09 2005 INSTALL OCCUPANCY SENSORS $1,797 $2,788 Implemented
WV0312 # 10 Y:2005 10 2005 UTILIZE A LESS EXPENSIVE COOLING METHOD $1,712 $824 Not Implemented
WV0312 # 11 Y:2005 11 2005 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,460 $0 Implemented
WV0312 # 12 Y:2005 12 2005 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $706 $120 Implemented
WV0312 # 13 Y:2005 13 2005 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $591 $130 Not Implemented
UU0084 # 01 Y:2005 01 2005 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,643 $6,171 Not Implemented
UU0084 # 02 Y:2005 02 2005 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $697 $2,150 Not Implemented
UU0084 # 03 Y:2005 03 2005 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,537 $0 Not Implemented
UU0084 # 04 Y:2005 04 2005 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $506 $235 Not Implemented
UU0084 # 05 Y:2005 05 2005 TURN OFF EQUIPMENT WHEN NOT IN USE $491 $200 Not Implemented
UU0084 # 06 Y:2005 06 2005 OPTIMIZE PLANT POWER FACTOR $4,429 $5,220 Not Implemented
UU0084 # 07 Y:2005 07 2005 COMBINE UTILITY METERS $575 $315 Not Implemented
UU0083 # 01 Y:2005 01 2005 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,340 $2,000 Not Implemented
UU0083 # 02 Y:2005 02 2005 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $760 $3,900 Not Implemented
UU0083 # 03 Y:2005 03 2005 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $7,880 $21,000 Not Implemented
UU0083 # 04 Y:2005 04 2005 VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE $5,640 $0 Not Implemented