Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,767
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0404 # 03 Y:1990 | 03 | 1990 | KEEP LAMPS AND REFLECTORS CLEAN | $2,724 | $11,289 | Not Implemented |
TN0404 # 04 Y:1990 | 04 | 1990 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $760 | $0 | Implemented |
TN0404 # 05 Y:1990 | 05 | 1990 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,475 | $1,140 | Not Implemented |
TN0404 # 06 Y:1990 | 06 | 1990 | INSTALL SET-BACK TIMERS | $1,258 | $0 | Implemented |
TN0404 # 07 Y:1990 | 07 | 1990 | USE COMPRESSOR AIR FILTERS | $716 | $50 | Implemented |
TN0404 # 08 Y:1990 | 08 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $195 | $0 | Implemented |
TN0404 # 09 Y:1990 | 09 | 1990 | IMPROVE LUBRICATION PRACTICES | $152 | $0 | Not Implemented |
TN0404 # 10 Y:1990 | 10 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $347 | $264 | Implemented |
TN0402 # 01 Y:1990 | 01 | 1990 | KEEP LAMPS AND REFLECTORS CLEAN | $4,123 | $11,116 | Implemented |
TN0402 # 02 Y:1990 | 02 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $2,474 | $4,140 | Implemented |
TN0402 # 03 Y:1990 | 03 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,428 | $960 | Implemented |
TN0402 # 04 Y:1990 | 04 | 1990 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,440 | $0 | Implemented |
TN0402 # 05 Y:1990 | 05 | 1990 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $925 | $0 | Implemented |
TN0402 # 06 Y:1990 | 06 | 1990 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $880 | $500 | Implemented |
TN0402 # 07 Y:1990 | 07 | 1990 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $780 | $660 | Not Implemented |
TN0402 # 08 Y:1990 | 08 | 1990 | DISCONNECT BALLASTS | $96 | $0 | Implemented |
TN0402 # 09 Y:1990 | 09 | 1990 | IMPROVE LUBRICATION PRACTICES | $57 | $30 | Not Implemented |
TN0403 # 01 Y:1990 | 01 | 1990 | REDUCE EXCESS STEAM BLEEDING | $5,335 | $1,280 | Implemented |
TN0403 # 02 Y:1990 | 02 | 1990 | INSULATE BARE EQUIPMENT | $4,167 | $2,442 | Not Implemented |
TN0403 # 03 Y:1990 | 03 | 1990 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $1,886 | $4,964 | Not Implemented |
TN0403 # 04 Y:1990 | 04 | 1990 | INSTALL / REPAIR INSULATION ON STEAM LINES | $501 | $356 | Implemented |
TN0403 # 05 Y:1990 | 05 | 1990 | INSTALL / REPAIR INSULATION ON CONDENSATE LINES | $213 | $300 | Implemented |
TN0403 # 06 Y:1990 | 06 | 1990 | INSTALL SET-BACK TIMERS | $532 | $0 | Implemented |
TN0403 # 07 Y:1990 | 07 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $742 | $236 | Implemented |
TN0403 # 08 Y:1990 | 08 | 1990 | IMPROVE LUBRICATION PRACTICES | $322 | $180 | Not Implemented |