Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,032
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0105 # 04 Y:1983 | 04 | 1983 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,827 | $2,400 | Implemented |
KU0097 # 01 Y:1983 | 01 | 1983 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $12,636 | $13,000 | Not Implemented |
KU0097 # 02 Y:1983 | 02 | 1983 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $10,812 | $8,500 | Not Implemented |
KU0097 # 03 Y:1983 | 03 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,389 | $4,629 | Not Implemented |
KU0097 # 04 Y:1983 | 04 | 1983 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,608 | $132 | Implemented |
KU0097 # 05 Y:1983 | 05 | 1983 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $2,533 | $2,500 | Not Implemented |
KU0097 # 06 Y:1983 | 06 | 1983 | OPTIMIZE PLANT POWER FACTOR | $1,494 | $2,800 | Not Implemented |
KU0097 # 07 Y:1983 | 07 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $727 | $200 | Implemented |
KU0097 # 08 Y:1983 | 08 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,237 | $410 | Implemented |
KU0097 # 09 Y:1983 | 09 | 1983 | INSTALL AUTOMATIC STACK DAMPER | $1,110 | $2,589 | Implemented |
KU0097 # 10 Y:1983 | 10 | 1983 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $983 | $192 | Implemented |
KU0097 # 11 Y:1983 | 11 | 1983 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $352 | $100 | Implemented |
KU0098 # 01 Y:1983 | 01 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,556 | $8,044 | Not Implemented |
KU0098 # 02 Y:1983 | 02 | 1983 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,062 | $371 | Implemented |
KU0098 # 03 Y:1983 | 03 | 1983 | INSTALL TIMERS AND/OR THERMOSTATS | $2,886 | $162 | Not Implemented |
KU0098 # 04 Y:1983 | 04 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $615 | $300 | Not Implemented |
KU0098 # 05 Y:1983 | 05 | 1983 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $580 | $510 | Not Implemented |
KU0098 # 06 Y:1983 | 06 | 1983 | INSTALL AUTOMATIC STACK DAMPER | $1,331 | $1,700 | Not Implemented |
KU0098 # 07 Y:1983 | 07 | 1983 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $2,452 | $300 | Not Implemented |
KU0098 # 08 Y:1983 | 08 | 1983 | AIR CONDITION ONLY SPACE NECESSARY | $4,385 | $0 | Not Implemented |
KU0098 # 09 Y:1983 | 09 | 1983 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $360 | $252 | Not Implemented |
KU0098 # 10 Y:1983 | 10 | 1983 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $6,750 | $7,400 | Not Implemented |
KU0098 # 11 Y:1983 | 11 | 1983 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,711 | $0 | Not Implemented |
KU0098 # 12 Y:1983 | 12 | 1983 | INSTALL SET-BACK TIMERS | $2,264 | $0 | Not Implemented |
KU0099 # 01 Y:1983 | 01 | 1983 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,778 | $2,585 | Implemented |