Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
6,403
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0059 # 03 Y:1996 | 03 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $710 | $1,200 | Implemented |
UM0059 # 04 Y:1996 | 04 | 1996 | INSTALL OCCUPANCY SENSORS | $973 | $74 | Implemented |
UM0059 # 05 Y:1996 | 05 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $920 | $507 | Implemented |
AS0178 # 01 Y:1996 | 01 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $224 | $0 | Implemented |
AS0178 # 02 Y:1996 | 02 | 1996 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,169 | $0 | Implemented |
AS0178 # 03 Y:1996 | 03 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,213 | $40 | Implemented |
AS0178 # 04 Y:1996 | 04 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,756 | $300 | Not Implemented |
AS0178 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $144 | $240 | Not Implemented |
AS0178 # 06 Y:1996 | 06 | 1996 | INSTALL OCCUPANCY SENSORS | $2,076 | $975 | Implemented |
AS0178 # 07 Y:1996 | 07 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,920 | $18,749 | Implemented |
AS0178 # 08 Y:1996 | 08 | 1996 | REDUCE VENTILATION AIR | $2,059 | $980 | Not Implemented |
AS0178 # 09 Y:1996 | 09 | 1996 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,510 | $0 | Implemented |
AS0178 # 10 Y:1996 | 10 | 1996 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $2,212 | $4,000 | Not Implemented |
AS0178 # 11 Y:1996 | 11 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $746 | $1,600 | Not Implemented |
AS0178 # 12 Y:1996 | 12 | 1996 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $1,455 | $0 | Implemented |
KG0062 # 01 Y:1996 | 01 | 1996 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $48,359 | $50 | Implemented |
KG0062 # 02 Y:1996 | 02 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $11,928 | $44,000 | Implemented |
KG0062 # 03 Y:1996 | 03 | 1996 | AVOID FROST FORMATION ON EVAPORATORS | $12,480 | $4,500 | Not Implemented |
KG0062 # 04 Y:1996 | 04 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $12,393 | $35,270 | Implemented |
KG0062 # 05 Y:1996 | 05 | 1996 | AVOID FROST FORMATION ON EVAPORATORS | $1,596 | $3,000 | Implemented |
KG0062 # 06 Y:1996 | 06 | 1996 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $906 | $2,204 | Implemented |
KG0062 # 07 Y:1996 | 07 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $629 | $314 | Implemented |
KG0062 # 08 Y:1996 | 08 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $599 | $300 | Not Implemented |
KG0062 # 09 Y:1996 | 09 | 1996 | TREAT AND REUSE RINSE WATERS | $21,972 | $0 | Implemented |
KG0062 # 10 Y:1996 | 10 | 1996 | TREAT AND REUSE RINSE WATERS | $23,328 | $0 | Not Implemented |