Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,777
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0138 # 02 Y:1992 | 02 | 1992 | OPTIMIZE PLANT POWER FACTOR | $2,460 | $640 | Implemented |
AM0138 # 03 Y:1992 | 03 | 1992 | INSTALL SET-BACK TIMERS | $940 | $0 | Implemented |
AM0138 # 04 Y:1992 | 04 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,147 | $2,720 | Implemented |
AM0139 # 01 Y:1992 | 01 | 1992 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $23,400 | $24,130 | Not Implemented |
AM0139 # 02 Y:1992 | 02 | 1992 | INSULATE BARE EQUIPMENT | $1,620 | $4,530 | Not Implemented |
AM0139 # 03 Y:1992 | 03 | 1992 | INSTALL SET-BACK TIMERS | $570 | $0 | Implemented |
AM0139 # 04 Y:1992 | 04 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,137 | $1,150 | Not Implemented |
AM0140 # 01 Y:1992 | 01 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,170 | $1,980 | Not Implemented |
AM0140 # 02 Y:1992 | 02 | 1992 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $430 | $1,000 | Not Implemented |
AM0140 # 03 Y:1992 | 03 | 1992 | INSTALL SET-BACK TIMERS | $150 | $310 | Not Implemented |
AM0140 # 04 Y:1992 | 04 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $222 | $142 | Not Implemented |
TN0447 # 01 Y:1992 | 01 | 1992 | INSTALL SET-BACK TIMERS | $9,430 | $11,500 | Not Implemented |
TN0447 # 02 Y:1992 | 02 | 1992 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $3,740 | $6,200 | Not Implemented |
TN0447 # 03 Y:1992 | 03 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,224 | $8,200 | Not Implemented |
TN0447 # 04 Y:1992 | 04 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $919 | $350 | Not Implemented |
TN0448 # 01 Y:1992 | 01 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,065 | $1,820 | Not Implemented |
TN0448 # 02 Y:1992 | 02 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $6,674 | $360 | Not Implemented |
TN0448 # 03 Y:1992 | 03 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,031 | $2,450 | Not Implemented |
TN0448 # 04 Y:1992 | 04 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $854 | $240 | Not Implemented |
TN0448 # 05 Y:1992 | 05 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,018 | $650 | Not Implemented |
TN0449 # 01 Y:1992 | 01 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $51,669 | $69,696 | Implemented |
TN0449 # 02 Y:1992 | 02 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,239 | $18,600 | Implemented |
TN0449 # 03 Y:1992 | 03 | 1992 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $8,635 | $5,425 | Implemented |
TN0449 # 04 Y:1992 | 04 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $13,284 | $2,175 | Implemented |
TN0449 # 05 Y:1992 | 05 | 1992 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $8,588 | $1,805 | Implemented |