Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,777

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0138 # 02 Y:1992 02 1992 OPTIMIZE PLANT POWER FACTOR $2,460 $640 Implemented
AM0138 # 03 Y:1992 03 1992 INSTALL SET-BACK TIMERS $940 $0 Implemented
AM0138 # 04 Y:1992 04 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,147 $2,720 Implemented
AM0139 # 01 Y:1992 01 1992 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $23,400 $24,130 Not Implemented
AM0139 # 02 Y:1992 02 1992 INSULATE BARE EQUIPMENT $1,620 $4,530 Not Implemented
AM0139 # 03 Y:1992 03 1992 INSTALL SET-BACK TIMERS $570 $0 Implemented
AM0139 # 04 Y:1992 04 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,137 $1,150 Not Implemented
AM0140 # 01 Y:1992 01 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,170 $1,980 Not Implemented
AM0140 # 02 Y:1992 02 1992 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $430 $1,000 Not Implemented
AM0140 # 03 Y:1992 03 1992 INSTALL SET-BACK TIMERS $150 $310 Not Implemented
AM0140 # 04 Y:1992 04 1992 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $222 $142 Not Implemented
TN0447 # 01 Y:1992 01 1992 INSTALL SET-BACK TIMERS $9,430 $11,500 Not Implemented
TN0447 # 02 Y:1992 02 1992 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $3,740 $6,200 Not Implemented
TN0447 # 03 Y:1992 03 1992 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $3,224 $8,200 Not Implemented
TN0447 # 04 Y:1992 04 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $919 $350 Not Implemented
TN0448 # 01 Y:1992 01 1992 RECOVER WASTE HEAT FROM EQUIPMENT $11,065 $1,820 Not Implemented
TN0448 # 02 Y:1992 02 1992 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $6,674 $360 Not Implemented
TN0448 # 03 Y:1992 03 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,031 $2,450 Not Implemented
TN0448 # 04 Y:1992 04 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $854 $240 Not Implemented
TN0448 # 05 Y:1992 05 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,018 $650 Not Implemented
TN0449 # 01 Y:1992 01 1992 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $51,669 $69,696 Implemented
TN0449 # 02 Y:1992 02 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $12,239 $18,600 Implemented
TN0449 # 03 Y:1992 03 1992 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $8,635 $5,425 Implemented
TN0449 # 04 Y:1992 04 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $13,284 $2,175 Implemented
TN0449 # 05 Y:1992 05 1992 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $8,588 $1,805 Implemented