Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,767
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0328 # 01 Y:1988 | 01 | 1988 | USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR | $18,715 | $40,300 | Implemented |
TN0328 # 02 Y:1988 | 02 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,135 | $0 | Implemented |
TN0328 # 03 Y:1988 | 03 | 1988 | INSTALL SET-BACK TIMERS | $1,617 | $0 | Implemented |
TN0328 # 04 Y:1988 | 04 | 1988 | REPAIR AND ELIMINATE STEAM LEAKS | $400 | $150 | Implemented |
TN0328 # 05 Y:1988 | 05 | 1988 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,244 | $4,554 | Not Implemented |
TN0328 # 06 Y:1988 | 06 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $916 | $590 | Implemented |
TN0328 # 07 Y:1988 | 07 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $563 | $90 | Implemented |
TN0324 # 01 Y:1987 | 01 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,756 | $300 | Implemented |
TN0324 # 02 Y:1987 | 02 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $906 | $585 | Implemented |
TN0324 # 03 Y:1987 | 03 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,612 | $4,800 | Implemented |
TN0324 # 04 Y:1987 | 04 | 1987 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,386 | $2,836 | Not Implemented |
TN0324 # 05 Y:1987 | 05 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,322 | $1,120 | Implemented |
TN0324 # 06 Y:1987 | 06 | 1987 | ADJUST VENTS TO MINIMIZE ENERGY USE | $967 | $0 | Implemented |
TN0324 # 07 Y:1987 | 07 | 1987 | IMPROVE LUBRICATION PRACTICES | $951 | $1,500 | Not Implemented |
TN0324 # 08 Y:1987 | 08 | 1987 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $822 | $1,360 | Implemented |
TN0324 # 09 Y:1987 | 09 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $790 | $192 | Implemented |
TN0324 # 10 Y:1987 | 10 | 1987 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $139 | $45 | Not Implemented |
TN0325 # 01 Y:1987 | 01 | 1987 | INSTALL / REPAIR INSULATION ON STEAM LINES | $10,904 | $421 | Implemented |
TN0325 # 02 Y:1987 | 02 | 1987 | USE MINIMUM STEAM OPERATING PRESSURE | $2,633 | $0 | Implemented |
TN0325 # 03 Y:1987 | 03 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,019 | $5,000 | Implemented |
TN0325 # 04 Y:1987 | 04 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,134 | $90 | Implemented |
TN0325 # 05 Y:1987 | 05 | 1987 | REPAIR AND ELIMINATE STEAM LEAKS | $849 | $75 | Implemented |
TN0325 # 06 Y:1987 | 06 | 1987 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $218 | $0 | Implemented |
TN0325 # 07 Y:1987 | 07 | 1987 | INSULATE BARE EQUIPMENT | $204 | $50 | Implemented |
TN0325 # 08 Y:1987 | 08 | 1987 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $217 | $0 | Not Implemented |