IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

4,184

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UM0025 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,153 $1,216 Not Implemented
UM0025 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,607 $28,762 Not Implemented
UM0025 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,494 $3,000 Not Implemented
UM0025 # 04 Y:1995 04 1995 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $1,581 $0 Not Implemented
UM0025 # 05 Y:1995 05 1995 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $6,138 $1,500 Not Implemented
UM0024 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $430 $460 Not Implemented
UM0024 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,581 $8,303 Not Implemented
UM0024 # 03 Y:1995 03 1995 INSTALL OCCUPANCY SENSORS $696 $1,980 Not Implemented
UM0023 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,365 $9,035 Not Implemented
UM0023 # 02 Y:1995 02 1995 COVER OPEN TANKS $12,514 $13,088 Implemented
UM0023 # 03 Y:1995 03 1995 DIRECT WARMEST AIR TO COMBUSTION INTAKE $684 $200 Not Implemented
UM0023 # 04 Y:1995 04 1995 INSULATE BARE EQUIPMENT $2,370 $481 Not Implemented
UM0023 # 05 Y:1995 05 1995 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS $3,126 $1,990 Not Implemented
UM0023 # 06 Y:1995 06 1995 INSTALL / REPAIR INSULATION ON STEAM LINES $3,012 $471 Not Implemented
UM0022 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $540 $367 Implemented
UM0022 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,344 $4,614 Implemented
UM0022 # 03 Y:1995 03 1995 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $31,536 $250 Implemented
UM0022 # 04 Y:1995 04 1995 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS $2,583 $6,080 Not Implemented
UM0021 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,209 $1,167 Implemented
UM0021 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,758 $5,594 Not Implemented
UM0021 # 03 Y:1995 03 1995 OPTIMIZE PLANT POWER FACTOR $1,047 $2,160 Not Implemented
UM0021 # 04 Y:1995 04 1995 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $28,057 $1,600 Not Implemented
UM0021 # 05 Y:1995 05 1995 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $13,180 $8,000 Not Implemented
UM0020 # 01 Y:1995 01 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $445 $747 Implemented
UM0020 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,545 $6,937 Implemented