Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 1995
Principal Product Polyurethane gaskets
NAICS n/a
SIC 3086 - Plastics Foam Products
Sales $10,000,000-$50,000,000
# of Employees 400
Plant Area (Sq.Ft.) 175,000
Annual Production 76,500 Pieces
Production Hrs. Annual 6,120
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $366,046 4,768,757 kWh $0.08
Natural Gas $100,920 25,400 MMBtu $3.97
TOTAL ENERGY COSTS $466,966
RECOMMENDED SAVINGS* $22,413 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$3,000
Cost:
$2,200
$3,000 38,980 - - $3,000
38,980
kWh
-
-
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$10,479
Cost:
$20,838
$10,479 138,921 - - $10,479
138,921
kWh
-
-
MMBtu
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$421
Cost:
$1,500
$421 7,620 - - $421
7,620
kWh
-
-
MMBtu
04: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$1,796
Cost:
$1,000
- - $1,796 463 -
-
kWh
$1,796
463
MMBtu
05: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$4,447
Cost:
$4,400
- - $4,447 1,146 -
-
kWh
$4,447
1,146
MMBtu
06: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$2,270
Cost:
$6,800
- - $2,270 585 -
-
kWh
$2,270
585
MMBtu
TOTAL RECOMMENDED Savings:
$22,413
Cost:
$36,738
$13,900 185,521 $8,513 2,194 $13,900
185,521
kWh
$8,513
2,194
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas