Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,644
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0137 # 03 Y:2002 | 03 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $43,767 | $25,000 | Not Implemented |
LE0137 # 04 Y:2002 | 04 | 2002 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,099 | $11,750 | Implemented |
LE0137 # 05 Y:2002 | 05 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,615 | $3,000 | Implemented |
LE0137 # 06 Y:2002 | 06 | 2002 | DO NOT USE COMPRESSED AIR FOR PERSONAL COOLING | $370 | $700 | Not Implemented |
LE0137 # 07 Y:2002 | 07 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,702 | $0 | Not Implemented |
LE0136 # 01 Y:2002 | 01 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,384 | $1,200 | Not Implemented |
LE0136 # 02 Y:2002 | 02 | 2002 | REPAIR OR REPLACE STEAM TRAPS | $34,475 | $17,000 | Not Implemented |
LE0136 # 03 Y:2002 | 03 | 2002 | RECOVER AND REUSE COOLING WATER | $1,527 | $2,000 | Not Implemented |
LE0136 # 04 Y:2002 | 04 | 2002 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $34,222 | $60,000 | Not Implemented |
LE0136 # 05 Y:2002 | 05 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $5,262 | $1,000 | Not Implemented |
LE0134 # 01 Y:2002 | 01 | 2002 | OPTIMIZE PLANT POWER FACTOR | $10,572 | $15,000 | Not Implemented |
LE0134 # 02 Y:2002 | 02 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $23,457 | $1,500 | Implemented |
LE0134 # 03 Y:2002 | 03 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,609 | $25,249 | Implemented |
LE0134 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $433 | $900 | Not Implemented |
LE0134 # 05 Y:2002 | 05 | 2002 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $1,721 | $245 | Not Implemented |
LE0134 # 06 Y:2002 | 06 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,676 | $1,200 | Implemented |
LE0133 # 01 Y:2002 | 01 | 2002 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $78,742 | $0 | Implemented |
LE0133 # 02 Y:2002 | 02 | 2002 | BURN A LESS EXPENSIVE GRADE OF FUEL | $1,298 | $6,000 | Not Implemented |
LE0133 # 03 Y:2002 | 03 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $983 | $0 | Implemented |
LE0133 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $349 | $750 | Not Implemented |
LE0133 # 05 Y:2002 | 05 | 2002 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $851 | $750 | Implemented |
LE0133 # 06 Y:2002 | 06 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,163 | $0 | Implemented |
LE0131 # 01 Y:2002 | 01 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $15,624 | $0 | Implemented |
LE0131 # 02 Y:2002 | 02 | 2002 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $11,376 | $4,500 | Implemented |
LE0131 # 03 Y:2002 | 03 | 2002 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,486 | $500 | Not Implemented |