Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,152
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0137 # 02 Y:1982 | 02 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $500 | $510 | Not Implemented |
TN0137 # 03 Y:1982 | 03 | 1982 | USE RADIANT HEATER FOR SPOT HEATING | $305 | $996 | Not Implemented |
TN0137 # 04 Y:1982 | 04 | 1982 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $131 | $0 | Not Implemented |
TN0139 # 01 Y:1982 | 01 | 1982 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $6,842 | $0 | Not Implemented |
TN0139 # 02 Y:1982 | 02 | 1982 | KEEP LAMPS AND REFLECTORS CLEAN | $2,000 | $0 | Not Implemented |
TN0139 # 03 Y:1982 | 03 | 1982 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $4,800 | $0 | Not Implemented |
TN0140 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $242 | $200 | Not Implemented |
TN0140 # 02 Y:1982 | 02 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $66 | $48 | Not Implemented |
TN0140 # 03 Y:1982 | 03 | 1982 | MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT | $185 | $0 | Not Implemented |
TN0142 # 01 Y:1982 | 01 | 1982 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $253 | $1,850 | Not Implemented |
TN0142 # 02 Y:1982 | 02 | 1982 | USE OPTIMUM THICKNESS INSULATION | $281 | $176 | Not Implemented |
TN0142 # 03 Y:1982 | 03 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $472 | $500 | Not Implemented |
TN0144 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,215 | $1,210 | Not Implemented |
TN0144 # 02 Y:1982 | 02 | 1982 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $2,100 | $0 | Not Implemented |
TN0149 # 01 Y:1982 | 01 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $230 | $0 | Not Implemented |
TN0149 # 02 Y:1982 | 02 | 1982 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,851 | $0 | Not Implemented |
TN0149 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,508 | $45,000 | Not Implemented |
KU0066 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,340 | $3,302 | Implemented |
KU0066 # 02 Y:1982 | 02 | 1982 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $1,820 | $0 | Implemented |
KU0066 # 03 Y:1982 | 03 | 1982 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $957 | $1,579 | Implemented |
KU0066 # 04 Y:1982 | 04 | 1982 | INSTALL AUTOMATIC STACK DAMPER | $560 | $582 | Implemented |
KU0066 # 05 Y:1982 | 05 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $341 | $200 | Implemented |
KU0066 # 06 Y:1982 | 06 | 1982 | OPTIMIZE PLANT POWER FACTOR | $1,172 | $2,350 | Not Implemented |
KU0067 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,109 | $4,780 | Not Implemented |
KU0067 # 02 Y:1982 | 02 | 1982 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,254 | $0 | Implemented |