Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
9,990
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0801 # 01 Y:2009 | 01 | 2009 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $18,742 | $14,833 | Implemented |
UD0801 # 02 Y:2009 | 02 | 2009 | REDUCE VENTILATION AIR | $10,610 | $14,833 | Implemented |
UD0801 # 03 Y:2009 | 03 | 2009 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $4,599 | $14,833 | Implemented |
UD0801 # 04 Y:2009 | 04 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,877 | $16,721 | Implemented |
UD0801 # 05 Y:2009 | 05 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,100 | $14,833 | Implemented |
UD0801 # 06 Y:2009 | 06 | 2009 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,087 | $0 | Not Implemented |
UD0801 # 07 Y:2009 | 07 | 2009 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $993 | $45,000 | Implemented |
UD0801 # 08 Y:2009 | 08 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $62 | $0 | Not Implemented |
UD0800 # 01 Y:2009 | 01 | 2009 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $42,596 | $0 | Not Implemented |
UD0800 # 02 Y:2009 | 02 | 2009 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $27,253 | $138,000 | Implemented |
UD0800 # 03 Y:2009 | 03 | 2009 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $18,713 | $7,500 | Not Implemented |
UD0800 # 04 Y:2009 | 04 | 2009 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $6,047 | $0 | Implemented |
UD0800 # 05 Y:2009 | 05 | 2009 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $3,892 | $2,000 | Not Implemented |
UD0800 # 06 Y:2009 | 06 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,306 | $0 | Implemented |
UD0800 # 07 Y:2009 | 07 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $700 | $4,239 | Implemented |
UD0800 # 08 Y:2009 | 08 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $444 | $1,000 | Implemented |
UD0800 # 09 Y:2009 | 09 | 2009 | METER RECYCLED WATER (TO REDUCE SEWER CHARGES) | $330 | $300 | Not Implemented |
UD0800 # 10 Y:2009 | 10 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $162 | $250 | Implemented |
WV0390 # 01 Y:2009 | 01 | 2009 | PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST | $138,137 | $122,000 | Not Implemented |
WV0390 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $29,790 | $72,987 | Implemented |
WV0390 # 03 Y:2009 | 03 | 2009 | OPTIMIZE PLANT POWER FACTOR | $20,264 | $4,490 | Implemented |
WV0390 # 04 Y:2009 | 04 | 2009 | USE RADIANT HEATER FOR SPOT HEATING | $20,144 | $22,048 | Not Implemented |
WV0390 # 05 Y:2009 | 05 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $16,484 | $11,250 | Not Implemented |
WV0390 # 06 Y:2009 | 06 | 2009 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $15,354 | $2,490 | Implemented |
WV0390 # 07 Y:2009 | 07 | 2009 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $15,020 | $2,500 | Implemented |