Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
4,043
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0628 # 08 Y:2013 | 08 | 2013 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $520 | $0 | Implemented |
AM0628 # 09 Y:2013 | 09 | 2013 | USE SYNTHETIC LUBRICANT | $240 | $0 | Not Implemented |
NC0475 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $28,801 | $48,075 | Not Implemented |
NC0475 # 02 Y:2013 | 02 | 2013 | INSTALL OCCUPANCY SENSORS | $9,597 | $5,600 | Not Implemented |
NC0475 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $975 | $1,124 | Not Implemented |
NC0475 # 04 Y:2013 | 04 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $620 | $100 | Not Implemented |
NC0475 # 05 Y:2013 | 05 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $11,988 | $4,750 | Not Implemented |
NC0475 # 06 Y:2013 | 06 | 2013 | REDUCE FLUID FLOW RATES | $16,217 | $25,000 | Not Implemented |
NC0474 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,078 | $1,180 | Implemented |
NC0474 # 04 Y:2013 | 04 | 2013 | USE PHOTOCELL CONTROLS | $3,817 | $7,000 | Not Implemented |
NC0474 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $1,019 | $3,470 | Implemented |
NC0474 # 06 Y:2013 | 06 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,431 | $1,000 | Implemented |
NC0474 # 07 Y:2013 | 07 | 2013 | USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER | $11,656 | $25,000 | Not Implemented |
NC0474 # 08 Y:2013 | 08 | 2013 | REPAIR OR REPLACE STEAM TRAPS | $13,419 | $5,700 | Implemented |
NC0474 # 09 Y:2013 | 09 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,672 | $100 | Implemented |
OK0838 # 01 Y:2013 | 01 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,128 | $0 | Implemented |
OK0838 # 02 Y:2013 | 02 | 2013 | COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER | $1,735 | $2,099 | Not Implemented |
OK0838 # 03 Y:2013 | 03 | 2013 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,393 | $2,746 | Implemented |
OK0838 # 04 Y:2013 | 04 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,439 | $28,635 | Not Implemented |
OK0838 # 05 Y:2013 | 05 | 2013 | INSTALL OCCUPANCY SENSORS | $501 | $2,086 | Not Implemented |
OK0838 # 06 Y:2013 | 06 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,834 | $9,882 | Not Implemented |
OK0838 # 07 Y:2013 | 07 | 2013 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $11,120 | $12,920 | Not Implemented |
OK0838 # 08 Y:2013 | 08 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,655 | $12,285 | Implemented |
OK0838 # 09 Y:2013 | 09 | 2013 | INSTALL TIMERS AND/OR THERMOSTATS | $5,387 | $1,980 | Implemented |
OK0838 # 10 Y:2013 | 10 | 2013 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $6,915 | $1,728 | Implemented |