Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,521
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0363 # 04 Y:1988 | 04 | 1988 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $12,120 | $4,685 | Not Implemented |
GT0363 # 05 Y:1988 | 05 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $472 | $377 | Not Implemented |
GT0363 # 06 Y:1988 | 06 | 1988 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $66,800 | $45,607 | Not Implemented |
GT0363 # 07 Y:1988 | 07 | 1988 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $11,540 | $32,000 | Not Implemented |
GT0363 # 08 Y:1988 | 08 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $163 | $150 | Not Implemented |
GT0354 # 01 Y:1988 | 01 | 1988 | INSTALL SET-BACK TIMERS | $10,948 | $1,800 | Not Implemented |
GT0354 # 02 Y:1988 | 02 | 1988 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $20,524 | $10,400 | Not Implemented |
GT0354 # 03 Y:1988 | 03 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,340 | $5,950 | Not Implemented |
GT0354 # 04 Y:1988 | 04 | 1988 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $25,532 | $80,640 | Not Implemented |
GT0355 # 01 Y:1988 | 01 | 1988 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $7,437 | $7,830 | Not Implemented |
GT0355 # 02 Y:1988 | 02 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $535 | $300 | Implemented |
GT0355 # 03 Y:1988 | 03 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $702 | $85 | Implemented |
GT0355 # 04 Y:1988 | 04 | 1988 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $136 | $140 | Not Implemented |
GT0355 # 05 Y:1988 | 05 | 1988 | USE RADIANT HEATER FOR SPOT HEATING | $11,594 | $25,480 | Implemented |
GT0344 # 01 Y:1988 | 01 | 1988 | TURN OFF EQUIPMENT WHEN NOT IN USE | $37,911 | $21,000 | Not Implemented |
GT0344 # 02 Y:1988 | 02 | 1988 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $2,970 | $2,830 | Not Implemented |
GT0344 # 03 Y:1988 | 03 | 1988 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,230 | $2,600 | Not Implemented |
GT0344 # 04 Y:1988 | 04 | 1988 | INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS | $90 | $35 | Not Implemented |
GT0344 # 05 Y:1988 | 05 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $140 | $0 | Not Implemented |
GT0344 # 06 Y:1988 | 06 | 1988 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $7,280 | $1,200 | Not Implemented |
GT0344 # 07 Y:1988 | 07 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,772 | $8,751 | Not Implemented |
GT0344 # 08 Y:1988 | 08 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $725 | $5,250 | Not Implemented |
GT0345 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,120 | $28,140 | Implemented |
GT0345 # 02 Y:1988 | 02 | 1988 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $400 | $180 | Implemented |
GT0345 # 03 Y:1988 | 03 | 1988 | INSTALL / REPAIR INSULATION ON STEAM LINES | $640 | $425 | Implemented |