Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,996
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ME0214 # 01 Y:1997 | 01 | 1997 | EMPLOY MODULAR JIGS TO REDUCE PROCESS SET-UP TIME | $24,500 | $7,500 | Implemented |
ME0214 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,079 | $31,719 | Implemented |
ME0214 # 03 Y:1997 | 03 | 1997 | PURCHASE APPROPRIATELY SIZED MATERIAL | $4,000 | $2,840 | Implemented |
ME0214 # 04 Y:1997 | 04 | 1997 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $2,400 | $800 | Not Implemented |
ME0214 # 05 Y:1997 | 05 | 1997 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,351 | $0 | Implemented |
ME0214 # 06 Y:1997 | 06 | 1997 | USE OPTIMUM THICKNESS INSULATION | $816 | $75 | Implemented |
ME0214 # 07 Y:1997 | 07 | 1997 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $604 | $0 | Not Implemented |
ME0214 # 08 Y:1997 | 08 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $387 | $30 | Implemented |
ME0214 # 09 Y:1997 | 09 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $832 | $6,200 | Implemented |
ME0214 # 10 Y:1997 | 10 | 1997 | REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS | $3,432 | $6,200 | Not Implemented |
MO0197 # 01 Y:1997 | 01 | 1997 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $16,060 | $15,000 | Implemented |
MO0197 # 02 Y:1997 | 02 | 1997 | BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE | $9,288 | $7,500 | Implemented |
MO0197 # 03 Y:1997 | 03 | 1997 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $4,800 | $10,000 | Implemented |
MO0197 # 04 Y:1997 | 04 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $13,642 | $0 | Implemented |
MO0197 # 05 Y:1997 | 05 | 1997 | IMPLEMENT A REGULAR MAINTENANCE PROGRAM TO REDUCE EMISSIONS FROM LEAKY VALVES AND PIPE FITTINGS | $1,052 | $3,000 | Implemented |
MO0197 # 06 Y:1997 | 06 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,247 | $4,192 | Implemented |
MO0197 # 07 Y:1997 | 07 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,358 | $1,718 | Implemented |
MO0197 # 08 Y:1997 | 08 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $303 | $0 | Implemented |
MO0197 # 09 Y:1997 | 09 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,128 | $337 | Implemented |
MO0197 # 10 Y:1997 | 10 | 1997 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $14,076 | $35,980 | Implemented |
SD0168 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $14,434 | $10,890 | Implemented |
SD0168 # 02 Y:1997 | 02 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $52,495 | $71,900 | Implemented |
SD0168 # 03 Y:1997 | 03 | 1997 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $958 | $1,100 | Implemented |
SD0168 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,736 | $7,712 | Implemented |
SD0168 # 05 Y:1997 | 05 | 1997 | INSTALL SPECTRAL REFLECTORS / DELAMP | $3,294 | $2,680 | Implemented |