IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,474

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
HO0069 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,846 $2,140 Not Implemented
HO0069 # 04 Y:1994 04 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,140 $1,000 Implemented
AS0113 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,597 $4,361 Not Implemented
AS0113 # 02 Y:1994 02 1994 USE PHOTOCELL CONTROLS $297 $30 Not Implemented
AS0113 # 03 Y:1994 03 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $381 $0 Not Implemented
AS0113 # 04 Y:1994 04 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $447 $250 Implemented
AS0113 # 05 Y:1994 05 1994 USE SYNTHETIC LUBRICANT $547 $2,110 Not Implemented
AS0113 # 06 Y:1994 06 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,076 $3,108 Implemented
AS0113 # 07 Y:1994 07 1994 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $11,531 $20,250 Not Implemented
TN0512 # 01 Y:1994 01 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,901 $840 Implemented
TN0512 # 02 Y:1994 02 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,241 $620 Not Implemented
TN0512 # 03 Y:1994 03 1994 USE SYNTHETIC LUBRICANT $3,076 $0 Not Implemented
TN0512 # 04 Y:1994 04 1994 INSTALL TIMERS AND/OR THERMOSTATS $997 $1,100 Not Implemented
TN0512 # 05 Y:1994 05 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $450 $280 Not Implemented
TN0512 # 06 Y:1994 06 1994 OPTIMIZE PLANT POWER FACTOR $5,590 $6,000 Not Implemented
OK0428 # 01 Y:1994 01 1994 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $1,053,065 $5,000,000 Not Implemented
OK0428 # 02 Y:1994 02 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $13,421 $16,008 Not Implemented
OK0428 # 03 Y:1994 03 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $10,778 $0 Not Implemented
OK0428 # 04 Y:1994 04 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,456 $0 Not Implemented
OK0428 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $705 $2,530 Not Implemented
NC0021 # 01 Y:1994 01 1994 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,164 $0 Implemented
NC0021 # 02 Y:1994 02 1994 ELIMINATE/REDUCE AN OPERATION $447 $500 Not Implemented
NC0021 # 03 Y:1994 03 1994 ELIMINATE/REDUCE AN OPERATION $10,452 $500 Not Implemented
NC0021 # 04 Y:1994 04 1994 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION $5,719 $8,750 Not Implemented
NC0021 # 05 Y:1994 05 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,913 $1,332 Not Implemented