IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,754

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0187 # 05 Y:1986 05 1986 USE RADIANT HEATER FOR SPOT HEATING $10,251 $54,400 Not Implemented
OK0184 # 01 Y:1986 01 1986 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $796 $50 Implemented
OK0184 # 02 Y:1986 02 1986 USE DEMAND CONTROLLER OR LOAD SHEDDER $1,732 $1,800 Implemented
OK0184 # 03 Y:1986 03 1986 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE $2,324 $1,200 Implemented
OK0184 # 04 Y:1986 04 1986 INSTALL TIMERS AND/OR THERMOSTATS $6,465 $2,800 Implemented
OK0185 # 01 Y:1986 01 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $166 $54 Implemented
OK0185 # 02 Y:1986 02 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $959 $120 Implemented
OK0185 # 03 Y:1986 03 1986 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $508 $1,300 Implemented
OK0185 # 04 Y:1986 04 1986 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $1,083 $3,050 Implemented
OK0186 # 01 Y:1986 01 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $678 $366 Implemented
OK0186 # 02 Y:1986 02 1986 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $46 $40 Implemented
OK0186 # 03 Y:1986 03 1986 COVER OPEN TANKS $3,068 $829 Implemented
OK0186 # 04 Y:1986 04 1986 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $832 $240 Implemented
OK0186 # 05 Y:1986 05 1986 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $328 $83 Implemented
OK0186 # 06 Y:1986 06 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $15,479 $1,500 Not Implemented
OK0186 # 07 Y:1986 07 1986 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $25,391 $21,000 Not Implemented
OK0183 # 01 Y:1986 01 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $791 $0 Implemented
OK0183 # 02 Y:1986 02 1986 INSTALL SET-BACK TIMERS $1,482 $845 Implemented
OK0183 # 03 Y:1986 03 1986 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $13,118 $36,015 Not Implemented
OK0183 # 04 Y:1986 04 1986 USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER $6,158 $5,270 Not Implemented
OK0183 # 05 Y:1986 05 1986 RECOVER AND REUSE COOLING WATER $34,172 $33,600 Not Implemented
OK0181 # 01 Y:1985 01 1985 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,786 $4,300 Not Implemented
OK0181 # 02 Y:1985 02 1985 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $2,120 $6,500 Not Implemented
OK0181 # 03 Y:1985 03 1985 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT $3,832 $2,940 Not Implemented
OK0181 # 04 Y:1985 04 1985 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $1,131 $579 Not Implemented