Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,521

matching recommendations
Reset
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0224 # 06 Y:1984 06 1984 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $180 $350 Not Implemented
GT0224 # 07 Y:1984 07 1984 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $1,190 $3,000 Not Implemented
GT0224 # 08 Y:1984 08 1984 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $1,780 $11,625 Not Implemented
GT0219 # 01 Y:1984 01 1984 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,420 $2,400 Implemented
GT0219 # 02 Y:1984 02 1984 INSTALL TIMERS AND/OR THERMOSTATS $4,440 $6,000 Implemented
GT0219 # 03 Y:1984 03 1984 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $319 $736 Not Implemented
GT0219 # 04 Y:1984 04 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,330 $295 Implemented
GT0219 # 05 Y:1984 05 1984 DISCONNECT BALLASTS $350 $303 Not Implemented
GT0220 # 01 Y:1984 01 1984 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $590 $1,200 Not Implemented
GT0220 # 02 Y:1984 02 1984 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $986 $1,840 Implemented
GT0220 # 03 Y:1984 03 1984 INSTALL TIMERS AND/OR THERMOSTATS $4,170 $3,000 Implemented
GT0220 # 04 Y:1984 04 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $301 $640 Implemented
GT0220 # 05 Y:1984 05 1984 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $76 $150 Implemented
GT0221 # 01 Y:1984 01 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,817 $500 Implemented
GT0221 # 02 Y:1984 02 1984 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER $4,716 $5,000 Not Implemented
GT0221 # 03 Y:1984 03 1984 INCREASE AMOUNT OF CONDENSATE RETURNED $18,719 $15,000 Not Implemented
GT0221 # 04 Y:1984 04 1984 INCREASE AMOUNT OF CONDENSATE RETURNED $2,089 $2,000 Not Implemented
GT0221 # 05 Y:1984 05 1984 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF $11,160 $10,000 Implemented
GT0221 # 06 Y:1984 06 1984 USE DEMAND CONTROLLER OR LOAD SHEDDER $23,900 $12,000 Not Implemented
GT0221 # 07 Y:1984 07 1984 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $6,879 $7,166 Not Implemented
GT0221 # 08 Y:1984 08 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,700 $3,780 Implemented
GT0231 # 01 Y:1984 01 1984 CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS $35,206 $60,000 Implemented
GT0231 # 02 Y:1984 02 1984 REDESIGN PROCESS $32,333 $20,000 Not Implemented
GT0231 # 03 Y:1984 03 1984 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $428 $592 Not Implemented
GT0231 # 04 Y:1984 04 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $570 $102 Implemented