Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
80
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0027 # 06 Y:1981 | 06 | 1981 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $160 | $300 | Not Implemented |
KU0029 # 03 Y:1981 | 03 | 1981 | REVISE SMOKE CLEANUP FROM OPERATIONS | $2,846 | $3,200 | Not Implemented |
KU0029 # 01 Y:1981 | 01 | 1981 | COVER OPEN TANKS | $2,125 | $55 | Implemented |
KU0027 # 04 Y:1981 | 04 | 1981 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $405 | $100 | Not Implemented |
UD0018 # 01 Y:1981 | 01 | 1981 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $610 | $45 | Not Implemented |
KU0026 # 01 Y:1981 | 01 | 1981 | OPTIMIZE PLANT POWER FACTOR | $6,100 | $8,200 | Not Implemented |
KU0029 # 07 Y:1981 | 07 | 1981 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $3,505 | $6,302 | Implemented |
KU0027 # 09 Y:1981 | 09 | 1981 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,720 | $5,466 | Not Implemented |
KU0027 # 07 Y:1981 | 07 | 1981 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $185 | $0 | Not Implemented |
KU0027 # 03 Y:1981 | 03 | 1981 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $700 | $0 | Not Implemented |
KU0028 # 02 Y:1981 | 02 | 1981 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,428 | $3,992 | Not Implemented |
KU0029 # 04 Y:1981 | 04 | 1981 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,911 | $0 | Implemented |
KU0022 # 01 Y:1981 | 01 | 1981 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,870 | $5,633 | Not Implemented |
KU0023 # 07 Y:1981 | 07 | 1981 | RECOVER WASTE HEAT FROM EQUIPMENT | $232 | $950 | Not Implemented |
KU0023 # 06 Y:1981 | 06 | 1981 | PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT | $374 | $1,280 | Not Implemented |
KU0023 # 05 Y:1981 | 05 | 1981 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $730 | $200 | Not Implemented |
KU0022 # 06 Y:1981 | 06 | 1981 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $620 | $1,620 | Implemented |
KU0022 # 05 Y:1981 | 05 | 1981 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $940 | $1,950 | Implemented |
KU0022 # 04 Y:1981 | 04 | 1981 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,185 | $2,850 | Not Implemented |
KU0022 # 03 Y:1981 | 03 | 1981 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $770 | $0 | Not Implemented |
KU0022 # 02 Y:1981 | 02 | 1981 | INSTALL TIMERS AND/OR THERMOSTATS | $2,320 | $1,500 | Implemented |
UD0016 # 04 Y:1981 | 04 | 1981 | USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS | $2,698 | $760 | Implemented |
UD0016 # 02 Y:1981 | 02 | 1981 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,251 | $752 | Implemented |
UD0016 # 03 Y:1981 | 03 | 1981 | USE OPTIMUM THICKNESS INSULATION | $245 | $0 | Implemented |
UD0016 # 05 Y:1981 | 05 | 1981 | INSTALL STORM WINDOWS AND DOORS | $1,452 | $1,208 | Implemented |