Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,263
matching recommendationsRow Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LS1722 # 04 Y:2022 | 04 | 2022 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $13,847 | $38,610 | Not Implemented |
LS1722 # 05 Y:2022 | 05 | 2022 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,108 | $22,697 | Implemented |
LS1622 # 01 Y:2022 | 01 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $3,718 | $350 | Implemented |
LS1622 # 02 Y:2022 | 02 | 2022 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $3,014 | $1,496 | Not Implemented |
LS1622 # 03 Y:2022 | 03 | 2022 | INSTALL OCCUPANCY SENSORS | $250 | $200 | Not Implemented |
LS1622 # 04 Y:2022 | 04 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,928 | $6,120 | Implemented |
LS1522 # 01 Y:2022 | 01 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $59,902 | $3,750 | Implemented |
LS1522 # 02 Y:2022 | 02 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $32,079 | $33,425 | Implemented |
LS1522 # 03 Y:2022 | 03 | 2022 | INSTALL OCCUPANCY SENSORS | $3,599 | $4,375 | Not Implemented |
LS1522 # 04 Y:2022 | 04 | 2022 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $702 | $1,050 | Not Implemented |
LS1522 # 05 Y:2022 | 05 | 2022 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $872 | $4,215 | Not Implemented |
LS1422 # 03 Y:2022 | 03 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,581 | $7,172 | Implemented |
LS1422 # 04 Y:2022 | 04 | 2022 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $5,400 | $11,760 | Not Implemented |
LS1422 # 05 Y:2022 | 05 | 2022 | LEVEL ONE – ADD COMMUNICATION USING IIOT DEVICES TO EXISTING CONTROL SYSTEM TO MODIFY OPERATIONS | $1,392 | $5,200 | Not Implemented |
LS1422 # 01 Y:2022 | 01 | 2022 | INSTALL OCCUPANCY SENSORS | $590 | $200 | Implemented |
LS1422 # 02 Y:2022 | 02 | 2022 | REDUCE HEAT GAIN BY WINDOW TINTING | $7,066 | $2,925 | Not Implemented |
LS1322 # 01 Y:2022 | 01 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $2,827 | $100 | Implemented |
LS1322 # 02 Y:2022 | 02 | 2022 | INSTALL OCCUPANCY SENSORS | $747 | $375 | Implemented |
LS1322 # 03 Y:2022 | 03 | 2022 | LEVEL ONE – ADD COMMUNICATION USING IIOT DEVICES TO EXISTING CONTROL SYSTEM TO MODIFY OPERATIONS | $5,493 | $3,200 | Not Implemented |
LS1322 # 04 Y:2022 | 04 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,044 | $31,514 | Implemented |
LS1222 # 01 Y:2022 | 01 | 2022 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $1,670 | $0 | Implemented |
LS1222 # 02 Y:2022 | 02 | 2022 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,620 | $0 | Implemented |
LS1222 # 03 Y:2022 | 03 | 2022 | INSTALL TIMERS AND/OR THERMOSTATS | $6,112 | $150 | Not Implemented |
LS1222 # 04 Y:2022 | 04 | 2022 | USE PHOTOCELL CONTROLS | $3,053 | $222 | Implemented |
LS1222 # 05 Y:2022 | 05 | 2022 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $19,500 | $11,480 | Not Implemented |